{"title":"Frequency-domain single-shot optical frequency comb tomography using VIPA","authors":"Takumi Miyaoka, T. Shioda","doi":"10.1117/12.2212093","DOIUrl":null,"url":null,"abstract":"Novel two-dimensional single-shot imaging optical system based on Frequency-domain interferometry using a virtually imaged phased array is proposed. The VIPA simultaneously outputs incoherent optical frequency combs (OFCs) whose teeth interval are scanned as a function of its output angle. Teeth intervals of the OFCs only in a reference are spatially swept by using of a VIPA whose advantage compared to an optical resonator. Thus, the single-shot imaging system can be realized with the FSR scanned frequency-domain OFC interference monitored by CCD. This system enable high speed 2-dimensional tomographic image without mechanical moving part. And the axial measurement range is not limited by using multi-order interference that is generated by OFCs interferometry. We will present the operation principle with its confirmed results in terms of both simulation and experiment.","PeriodicalId":122702,"journal":{"name":"SPIE OPTO","volume":"150 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-03-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SPIE OPTO","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2212093","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Novel two-dimensional single-shot imaging optical system based on Frequency-domain interferometry using a virtually imaged phased array is proposed. The VIPA simultaneously outputs incoherent optical frequency combs (OFCs) whose teeth interval are scanned as a function of its output angle. Teeth intervals of the OFCs only in a reference are spatially swept by using of a VIPA whose advantage compared to an optical resonator. Thus, the single-shot imaging system can be realized with the FSR scanned frequency-domain OFC interference monitored by CCD. This system enable high speed 2-dimensional tomographic image without mechanical moving part. And the axial measurement range is not limited by using multi-order interference that is generated by OFCs interferometry. We will present the operation principle with its confirmed results in terms of both simulation and experiment.