Voltage-Stability Monitoring Using Wide-Area Measurement Systems

B. Genet, J. Maun
{"title":"Voltage-Stability Monitoring Using Wide-Area Measurement Systems","authors":"B. Genet, J. Maun","doi":"10.1109/PCT.2007.4538573","DOIUrl":null,"url":null,"abstract":"A new monitoring method based on a wide-area network of Phaser Measurement Units (PMU) is proposed. This tool detects on-line and in real-time an incipient voltage instability in the power system. A geographical visualization is introduced to monitor efficiently the state of the network. The method is general and can be implemented in any part of a network prone to voltage instability. It can be used to trigger corrective actions to avoid a collapse. The hypotheses and the results of the new method will be discussed in regard with those given by the Thevenin's equivalent computed at the load bus.","PeriodicalId":356805,"journal":{"name":"2007 IEEE Lausanne Power Tech","volume":"52 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"29","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE Lausanne Power Tech","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PCT.2007.4538573","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 29

Abstract

A new monitoring method based on a wide-area network of Phaser Measurement Units (PMU) is proposed. This tool detects on-line and in real-time an incipient voltage instability in the power system. A geographical visualization is introduced to monitor efficiently the state of the network. The method is general and can be implemented in any part of a network prone to voltage instability. It can be used to trigger corrective actions to avoid a collapse. The hypotheses and the results of the new method will be discussed in regard with those given by the Thevenin's equivalent computed at the load bus.
使用广域测量系统的电压稳定性监测
提出了一种基于相位测量单元(PMU)广域网的新型监测方法。该工具在线和实时检测电力系统的初期电压不稳定。为了有效地监控网络状态,引入了地理可视化技术。该方法具有通用性,可应用于电网中电压不稳定的任何部分。它可以用来触发纠正措施,以避免崩溃。新方法的假设和结果将与在负载母线上计算的Thevenin等效给出的假设和结果进行讨论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信