A microstrip resonant biosensor for aqueous glucose detection in microfluidic medical applications

U. Schwerthoeffer, Christopher Warter, R. Weigel, D. Kissinger
{"title":"A microstrip resonant biosensor for aqueous glucose detection in microfluidic medical applications","authors":"U. Schwerthoeffer, Christopher Warter, R. Weigel, D. Kissinger","doi":"10.1109/BIOWIRELESS.2014.6827728","DOIUrl":null,"url":null,"abstract":"A highly sensitive biosensor to detect small variations of glucose concentrations in water is proposed. The sensor structure is based on a planar half-wavelength (lambda/2) microstrip line (MSL) resonator with a microflu-idic container placed on top. The interaction between the electric field and the milliliter range water-glucose solutions under test can be observed measuring the phase shift of the S-parameter from 3.95 to 4.10 GHz. Combining the microwave detection and the microfluidic network, a time efficient and low cost architecture is presented. With this technique, a very sensitive water-glucose concentration of less than 50 mg/dl can be separated.","PeriodicalId":341652,"journal":{"name":"2014 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIOWIRELESS.2014.6827728","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

A highly sensitive biosensor to detect small variations of glucose concentrations in water is proposed. The sensor structure is based on a planar half-wavelength (lambda/2) microstrip line (MSL) resonator with a microflu-idic container placed on top. The interaction between the electric field and the milliliter range water-glucose solutions under test can be observed measuring the phase shift of the S-parameter from 3.95 to 4.10 GHz. Combining the microwave detection and the microfluidic network, a time efficient and low cost architecture is presented. With this technique, a very sensitive water-glucose concentration of less than 50 mg/dl can be separated.
用于微流控医学中葡萄糖检测的微带共振生物传感器
提出了一种高灵敏度的生物传感器,用于检测水中葡萄糖浓度的微小变化。传感器结构基于平面半波长(λ /2)微带线(MSL)谐振器,顶部放置微流体容器。通过测量s参数在3.95 ~ 4.10 GHz范围内的相移,可以观察到电场与毫升范围内的水-葡萄糖溶液之间的相互作用。将微波检测与微流控网络相结合,提出了一种省时、低成本的微流控网络结构。使用这种技术,可以分离出低于50 mg/dl的非常敏感的水-葡萄糖浓度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信