Instrument for MTF Measurements of Cataractous Eyes

P. Magnante, Barry Fadden
{"title":"Instrument for MTF Measurements of Cataractous Eyes","authors":"P. Magnante, Barry Fadden","doi":"10.1364/vsia.1997.saa.3","DOIUrl":null,"url":null,"abstract":"With approximately 1.5 million cataract surgeries performed each year in the United States, there is great need for a non-invasive ophthalmic instrument that measures objectively the inability of a cataractous eye to produce clear images. We describe here the construction and operation of a new instrument which meets this need. Called the Ocular Resolution Analyzer (ORA), the instrument projects a fine line on a patient's retina, records the blurred retinal line image, and quantifies the extent of blurring by computing the Modulation Transfer Function. In clinical tests on cataract patients, increased blurring measured by the ORA has been shown to correlate with other indicators of cataract development: 1) increasing lens opacification as observed with a slit lamp,1 2) loss of visual acuity,2 3) loss of contrast sensitivity, and 4) increased glare sensitivity.3","PeriodicalId":428257,"journal":{"name":"Vision Science and its Applications","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vision Science and its Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1364/vsia.1997.saa.3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

With approximately 1.5 million cataract surgeries performed each year in the United States, there is great need for a non-invasive ophthalmic instrument that measures objectively the inability of a cataractous eye to produce clear images. We describe here the construction and operation of a new instrument which meets this need. Called the Ocular Resolution Analyzer (ORA), the instrument projects a fine line on a patient's retina, records the blurred retinal line image, and quantifies the extent of blurring by computing the Modulation Transfer Function. In clinical tests on cataract patients, increased blurring measured by the ORA has been shown to correlate with other indicators of cataract development: 1) increasing lens opacification as observed with a slit lamp,1 2) loss of visual acuity,2 3) loss of contrast sensitivity, and 4) increased glare sensitivity.3
白内障眼MTF测量仪
在美国,每年大约有150万例白内障手术,因此非常需要一种非侵入性的眼科仪器来客观地测量白内障眼产生清晰图像的能力。我们在这里描述了一种满足这一需求的新仪器的结构和操作。该仪器被称为眼分辨率分析仪(ORA),它在患者的视网膜上投射一条细线,记录模糊的视网膜线图像,并通过计算调制传递函数来量化模糊的程度。在对白内障患者的临床试验中,ORA测量的模糊度增加与白内障发展的其他指标相关:1)裂隙灯观察到晶状体混浊度增加,12)视力下降,2)对比敏感度下降,4)眩光敏感度增加
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信