Influence of temperature on tan-delta of XLPE cables

A. Adeniyi, J.J. Walker, C. Nyamupangedengu
{"title":"Influence of temperature on tan-delta of XLPE cables","authors":"A. Adeniyi, J.J. Walker, C. Nyamupangedengu","doi":"10.1109/ROBOMECH.2019.8704739","DOIUrl":null,"url":null,"abstract":"The quality of cable insulation in high voltage systems is of important concern. The cable insulation degradation is influenced by service condition and environmental impacts. This paper contributes to the knowledge on the influence of temperature on tan-delta of XLPE cable through an experimental investigation. The laboratory test experiment was conducted on cable samples of 10 meters each with terminations and without terminations at temperature ranges of 200 – 700C to evaluate the influence of temperature and terminations on tan-delta. The results show that tan-delta values of XLPE cables are influenced by insulation temperature.","PeriodicalId":344332,"journal":{"name":"2019 Southern African Universities Power Engineering Conference/Robotics and Mechatronics/Pattern Recognition Association of South Africa (SAUPEC/RobMech/PRASA)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 Southern African Universities Power Engineering Conference/Robotics and Mechatronics/Pattern Recognition Association of South Africa (SAUPEC/RobMech/PRASA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ROBOMECH.2019.8704739","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The quality of cable insulation in high voltage systems is of important concern. The cable insulation degradation is influenced by service condition and environmental impacts. This paper contributes to the knowledge on the influence of temperature on tan-delta of XLPE cable through an experimental investigation. The laboratory test experiment was conducted on cable samples of 10 meters each with terminations and without terminations at temperature ranges of 200 – 700C to evaluate the influence of temperature and terminations on tan-delta. The results show that tan-delta values of XLPE cables are influenced by insulation temperature.
温度对交联聚乙烯电缆tan-delta的影响
高压系统中电缆的绝缘质量是一个重要的问题。电缆的绝缘劣化受使用条件和环境的影响。本文通过实验研究,对温度对交联聚乙烯电缆tan-delta的影响有所了解。在200 - 700C的温度范围内,对带端接和不带端接的10米电缆样品进行室内测试实验,评价温度和端接对tan-delta的影响。结果表明,交联聚乙烯电缆的tan-delta值受绝缘温度的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信