A. Cavallini, Luca Lusardi, A. Rumi, K. Kimura, A. Contin, T. Han
{"title":"Searching for Optimal Connection Schemes for Partial Discharge Testing of Inverter-Fed Rotating Machines","authors":"A. Cavallini, Luca Lusardi, A. Rumi, K. Kimura, A. Contin, T. Han","doi":"10.1109/EIC43217.2019.9046521","DOIUrl":null,"url":null,"abstract":"Partial discharge testing of complete, low voltage induction machines using the configurations proposed in the IEC 60034-27-5CD, is discussed. Based on tests performed on a machine with accessible coil terminals, the most promising configurations for type tests and quality control, is proposed and the limits of the IEC 60034-18-41 highlighted.","PeriodicalId":340602,"journal":{"name":"2019 IEEE Electrical Insulation Conference (EIC)","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Electrical Insulation Conference (EIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIC43217.2019.9046521","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Partial discharge testing of complete, low voltage induction machines using the configurations proposed in the IEC 60034-27-5CD, is discussed. Based on tests performed on a machine with accessible coil terminals, the most promising configurations for type tests and quality control, is proposed and the limits of the IEC 60034-18-41 highlighted.