{"title":"MRI inter-packet movement correction for images acquired with non-complementary data","authors":"E. Gedamu, Abraham Gedamu, D. Arnold, D. Collins","doi":"10.1109/ISBI.2008.4541021","DOIUrl":null,"url":null,"abstract":"Movement during the acquisition of magnetic resonance images can cause artifacts that interfere with subsequent image analysis. In this paper we address the problem of inter-packet motion and provide a method to minimize errors associated with this artifact. The procedure is based on an iterative packet-to-volume registration process and does not require complementary information such as multimodal acquisitions or protocols that provide redundant volume data. A Kaiser-Bessel function is used to interpolate missing data. Experiments with simulated data demonstrate that the packet-to-volume registration improves greatly after a single iteration and maintains improvement for the following iterations, while experiments with real data demonstrate a substantial reduction in associated artifacts and improvement in quality. In both cases anatomical integrity is preserved after reconstruction.","PeriodicalId":184204,"journal":{"name":"2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro","volume":"114 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-05-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISBI.2008.4541021","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Movement during the acquisition of magnetic resonance images can cause artifacts that interfere with subsequent image analysis. In this paper we address the problem of inter-packet motion and provide a method to minimize errors associated with this artifact. The procedure is based on an iterative packet-to-volume registration process and does not require complementary information such as multimodal acquisitions or protocols that provide redundant volume data. A Kaiser-Bessel function is used to interpolate missing data. Experiments with simulated data demonstrate that the packet-to-volume registration improves greatly after a single iteration and maintains improvement for the following iterations, while experiments with real data demonstrate a substantial reduction in associated artifacts and improvement in quality. In both cases anatomical integrity is preserved after reconstruction.
非互补数据获取图像的MRI包间运动校正
在磁共振图像采集过程中的运动可能导致干扰后续图像分析的伪影。在本文中,我们解决了包间运动的问题,并提供了一种方法来最小化与该工件相关的错误。该程序基于迭代的包到卷注册过程,不需要补充信息,如多模式采集或提供冗余卷数据的协议。使用Kaiser-Bessel函数来插值缺失的数据。用模拟数据进行的实验表明,在一次迭代之后,包到卷的注册得到了极大的改进,并在随后的迭代中保持了改进,而用真实数据进行的实验表明,相关的工件大大减少,质量得到了提高。在这两种情况下,重建后都保持了解剖的完整性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信