{"title":"ACCOUNTING FOR THE INFLUENCE \nOF HUMIDITY PROPERTIES OF AUTOCLAVE- \nCURED CELLULAR CONCRETE \nIN THE DESIGN AND CONSTRUCTION \nOF ENCLOSING STRUCTURES","authors":"V. Strotskiy, A. Krokhin, V. Savin","doi":"10.37538/2224-9494-2021-3(30)-88-99","DOIUrl":null,"url":null,"abstract":"The results of studies of porosity, water \nabsorption, moisture shrinkage and frost \nresistance of cellular concrete, which are some \nof the main factors determining the durability \nof cellular concrete enclosing structures \nmanufactured using autoclave hardening \ntechnology, are considered. \nMethods for determining water absorption, \nmoisture shrinkage and frost resistance are \npresented. The relationship between the \nmoisture shrinkage and the capillary forces \n(the sum of the surface tension forces on the \nmicromeniscs of liquid in the capillaries of \ncellular concrete), as well as the dependence \nof the shrinkage on the size (radius) of the \ncapillary and gas pores of cellular concreteand on the water-solid ratio (W/S-factor) of \ncellular concrete, is established. \nIn the field of frost resistance of cellular \nconcrete, the relationship between the \nstructure of the pore space of concrete \nand its deformation characteristics under \nthe action of negative temperatures is studied. \nThe effect of the presence of gas pores in \ncellular concrete on the reduction of frost \nexpansion deformations is described.","PeriodicalId":332973,"journal":{"name":"Bulletin of Science and Research Center “Stroitelstvo”","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin of Science and Research Center “Stroitelstvo”","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.37538/2224-9494-2021-3(30)-88-99","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The results of studies of porosity, water
absorption, moisture shrinkage and frost
resistance of cellular concrete, which are some
of the main factors determining the durability
of cellular concrete enclosing structures
manufactured using autoclave hardening
technology, are considered.
Methods for determining water absorption,
moisture shrinkage and frost resistance are
presented. The relationship between the
moisture shrinkage and the capillary forces
(the sum of the surface tension forces on the
micromeniscs of liquid in the capillaries of
cellular concrete), as well as the dependence
of the shrinkage on the size (radius) of the
capillary and gas pores of cellular concreteand on the water-solid ratio (W/S-factor) of
cellular concrete, is established.
In the field of frost resistance of cellular
concrete, the relationship between the
structure of the pore space of concrete
and its deformation characteristics under
the action of negative temperatures is studied.
The effect of the presence of gas pores in
cellular concrete on the reduction of frost