Generator condition monitor evolution and capability

C. Maughan, P. E. Emeritus
{"title":"Generator condition monitor evolution and capability","authors":"C. Maughan, P. E. Emeritus","doi":"10.1109/EEIC.2007.4562587","DOIUrl":null,"url":null,"abstract":"The generator condition monitor (also called \"core monitor\") had an early history of invalid alarms due to causes not related to generator overheating. Because responding to a monitor alarm involved high cost to the owner, it became common industry practice to ignore the device. Yet even on the early, somewhat primitive instruments, valid alarms occurred. Because of the potentially high value of early detection of burning inside a generator, a large effort has been expended to improve reliability of the device and make it easier to use. These efforts involved both present suppliers of this equipment, general electric & environment one, as well as others. Around 1989 a mature design had been reached, and since then over 500 of the modern devices have been put in service. Based on recent EPRI surveys and other data sources, the post-1989 monitors are now performing well, with infrequent invalid alarms. Seventeen valid alarms have been reported on generators, and these incidents are summarized individually in this paper. Although the number of valid alarms is small, because of the inherently high destructive nature of these failures the potential saving has been great . A single failure can exceed $10 million in repair cost alone, and forced outage time costs can far exceed the high repair costs. Correct response to the infrequent monitor alarm has been enhanced by the availability of the distributed control system. If properly maintained and operated, the generator condition monitor can be a valuable device that could mean the difference between a brief shut down for minor repairs or a major overhaul involving weeks or even months of costly downtime.","PeriodicalId":152045,"journal":{"name":"2007 Electrical Insulation Conference and Electrical Manufacturing Expo","volume":"80 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 Electrical Insulation Conference and Electrical Manufacturing Expo","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEIC.2007.4562587","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

The generator condition monitor (also called "core monitor") had an early history of invalid alarms due to causes not related to generator overheating. Because responding to a monitor alarm involved high cost to the owner, it became common industry practice to ignore the device. Yet even on the early, somewhat primitive instruments, valid alarms occurred. Because of the potentially high value of early detection of burning inside a generator, a large effort has been expended to improve reliability of the device and make it easier to use. These efforts involved both present suppliers of this equipment, general electric & environment one, as well as others. Around 1989 a mature design had been reached, and since then over 500 of the modern devices have been put in service. Based on recent EPRI surveys and other data sources, the post-1989 monitors are now performing well, with infrequent invalid alarms. Seventeen valid alarms have been reported on generators, and these incidents are summarized individually in this paper. Although the number of valid alarms is small, because of the inherently high destructive nature of these failures the potential saving has been great . A single failure can exceed $10 million in repair cost alone, and forced outage time costs can far exceed the high repair costs. Correct response to the infrequent monitor alarm has been enhanced by the availability of the distributed control system. If properly maintained and operated, the generator condition monitor can be a valuable device that could mean the difference between a brief shut down for minor repairs or a major overhaul involving weeks or even months of costly downtime.
发电机状态监测的发展和能力
发电机状态监视器(也称为“核心监视器”)有一个早期的无效警报历史,由于与发电机过热无关的原因。由于响应监视器警报对所有者来说成本很高,因此忽略该设备已成为常见的行业惯例。然而,即使在早期的、有些原始的仪器上,也会发生有效的警报。由于发电机内部燃烧的早期检测具有潜在的高价值,因此人们花费了大量精力来提高设备的可靠性并使其更易于使用。这些努力涉及到该设备的现有供应商,通用电气和环境公司,以及其他公司。大约在1989年达到了一个成熟的设计,从那时起,已有500多台现代化设备投入使用。根据最近的EPRI调查和其他数据来源,1989年后的监视器现在表现良好,很少出现无效警报。共报告了17起有效的发电机报警事件,并对这些事件逐一进行了总结。虽然有效警报的数量很少,但由于这些故障固有的高破坏性,潜在的节省是巨大的。单是一次故障的维修成本就可能超过1000万美元,而强制停机时间的成本远远超过高昂的维修成本。分布式控制系统的可用性提高了对不频繁的监控报警的正确响应。如果维护和操作得当,发电机状态监视器可能是一个有价值的设备,它可能意味着短暂停机进行小修或涉及数周甚至数月的昂贵停机时间的大修之间的区别。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信