{"title":"Instability in induction generator based wind farms connected to series compensated transmission lines","authors":"A. Moharana, R. Varma","doi":"10.1109/ICEAS.2011.6147125","DOIUrl":null,"url":null,"abstract":"This paper presents a study of subsynchronous mode instability in Induction Generator (IG) based wind farm connected to a series compensated transmission line. The IEEE First SSR benchmark system is modified by replacing the synchronous generator with an aggregated wind farm. A small signal stability analysis is carried out to detect the instability analytically and then results are validated through a detailed electromagnetic transient simulation using PSCAD/EMTDC. Two types of studies are performed for the small signal analysis. First, a linearized state space model is developed for the eigenvalue calculation. Then, a simple equivalent circuit model is developed for the resonant speed analysis. From the equivalent circuit model, two resonant speeds - upper resonant speed (URS) and lower resonant speed (LRS), are obtained. If the post fault speed of the aggregated generator comes close or enters in the band within these two resonant speeds, the induction generator may become unstable. The performance of the aggregated wind farm model is validated with a distributed wind farm model. It is shown that the wind generator may experience SSR if the fault occurs at the terminals of the wind farm even at a realistic level of series compensation.","PeriodicalId":273164,"journal":{"name":"2011 International Conference on Energy, Automation and Signal","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Energy, Automation and Signal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEAS.2011.6147125","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
This paper presents a study of subsynchronous mode instability in Induction Generator (IG) based wind farm connected to a series compensated transmission line. The IEEE First SSR benchmark system is modified by replacing the synchronous generator with an aggregated wind farm. A small signal stability analysis is carried out to detect the instability analytically and then results are validated through a detailed electromagnetic transient simulation using PSCAD/EMTDC. Two types of studies are performed for the small signal analysis. First, a linearized state space model is developed for the eigenvalue calculation. Then, a simple equivalent circuit model is developed for the resonant speed analysis. From the equivalent circuit model, two resonant speeds - upper resonant speed (URS) and lower resonant speed (LRS), are obtained. If the post fault speed of the aggregated generator comes close or enters in the band within these two resonant speeds, the induction generator may become unstable. The performance of the aggregated wind farm model is validated with a distributed wind farm model. It is shown that the wind generator may experience SSR if the fault occurs at the terminals of the wind farm even at a realistic level of series compensation.
本文研究了与串联补偿输电线路连接的感应发电机(IG)风电场的次同步模式失稳问题。通过将同步发电机替换为聚合风电场,改进了IEEE First SSR基准系统。通过小信号稳定性分析,对系统的不稳定性进行了分析检测,并利用PSCAD/EMTDC进行了详细的电磁瞬变仿真,对结果进行了验证。对小信号分析进行了两种类型的研究。首先,建立了一个线性化的状态空间模型,用于特征值的计算。然后,建立了一个简单的等效电路模型来分析谐振速度。从等效电路模型出发,得到了两个谐振速度——上谐振速度(URS)和下谐振速度(LRS)。如果聚合发电机的后故障速度接近或进入这两个谐振速度范围内,则感应发电机可能会变得不稳定。用分布式风电场模型验证了聚合风电场模型的性能。结果表明,即使在实际的串联补偿水平下,如果故障发生在风电场的末端,风力发电机也可能发生SSR。