M. Chmelevsky, M. Budanova, S. Zubarev, D. Potyagaylo, T. Treshkur, D. Lebedev
{"title":"Clinical Evaluation of Noninvasive ECGI Epi-Endocardial Mapping Accuracy","authors":"M. Chmelevsky, M. Budanova, S. Zubarev, D. Potyagaylo, T. Treshkur, D. Lebedev","doi":"10.22489/CinC.2018.387","DOIUrl":null,"url":null,"abstract":"Although ECG imaging technology has been in development for many years, the clinical validation of epi-endocardial ECGI mapping has been conducted only on relatively small groups of patients. This study was performed to evaluate epi-endocardial ECGI mapping accuracy for the pacings from implanted pacemakers in a single center single-blind cross-sectional study. Thirty patients with previously implanted pacemakers underwent epi-endocardial ECGI mapping using “Amycard 01C EP Lab” system (EP Solutions SA, Switzerland). The median (25-75% IQR) geodesic distance between noninvasively reconstructed and the reference pacing sites was 8 (5–11) mm for the LV epicardial and 4 (2–6) mm for the RV endocardial pacings. This study showed sufficient accuracy of epi-endocarial ECGI technology to use it in a routine clinical practice for identification of focal arrhythmia sources.","PeriodicalId":215521,"journal":{"name":"2018 Computing in Cardiology Conference (CinC)","volume":"57 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 Computing in Cardiology Conference (CinC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22489/CinC.2018.387","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9
Abstract
Although ECG imaging technology has been in development for many years, the clinical validation of epi-endocardial ECGI mapping has been conducted only on relatively small groups of patients. This study was performed to evaluate epi-endocardial ECGI mapping accuracy for the pacings from implanted pacemakers in a single center single-blind cross-sectional study. Thirty patients with previously implanted pacemakers underwent epi-endocardial ECGI mapping using “Amycard 01C EP Lab” system (EP Solutions SA, Switzerland). The median (25-75% IQR) geodesic distance between noninvasively reconstructed and the reference pacing sites was 8 (5–11) mm for the LV epicardial and 4 (2–6) mm for the RV endocardial pacings. This study showed sufficient accuracy of epi-endocarial ECGI technology to use it in a routine clinical practice for identification of focal arrhythmia sources.