Criteria for the Applicability of Computer Vision for Preventive Studies on the Example of Chest X-Ray and Fluorography

K. Arzamasov, S. Semenov, D. Kokina, T. Bobrovskaya, N. Pavlov, Y. Kirpichev, A. Andreychenko, A. Vladzymyrskyy
{"title":"Criteria for the Applicability of Computer Vision for Preventive Studies on the Example of Chest X-Ray and Fluorography","authors":"K. Arzamasov, S. Semenov, D. Kokina, T. Bobrovskaya, N. Pavlov, Y. Kirpichev, A. Andreychenko, A. Vladzymyrskyy","doi":"10.52775/1810-200x-2022-96-4-56-63","DOIUrl":null,"url":null,"abstract":"Purpose: In the conditions of a constant increase in the number of computer vision algorithms developed based on artificial intelligence (AI) for medical diagnostics, it becomes necessary to determine criteria for deciding whether their practical application for mass preventive studies of the population is appropriate. \nMaterials and methods: The study with the participation of several radiologists was conducted on a “Web platform for evaluating radiological studies” on a marked data set containing digital radiographs and fluorograms in an anterior direct projection. On the same data set, using the “Versioning Testing Platform”, responses were obtained from two commercial AI-based computer vision algorithms developed for the analysis of digital radiographs. Evaluation of the results obtained from doctors and algorithms (binary, in terms of “with pathology” and “without pathology”) was carried out using ROC analysis. For the threshold value calculated by the Yuden method, the following metrics were determined: sensitivity, specificity and accuracy. \nResults: diagnostic accuracy metrics were calculated for the average assessment of radiologists and AI-based computer vision algorithms when searching for pathological changes on chest X-rays in anterior direct projection according to ROC analysis. The average values of diagnostic accuracy indicators of radiologists exceeded the indicators of AI services. \nConclusions: when deciding on the implementation of AI-based computer vision algorithms for preventive research, One should be guided by the metrics of diagnostic accuracy of a particular algorithm and use the average result of doctors in solving this diagnostic problem as the target values of metrics.","PeriodicalId":222791,"journal":{"name":"Meditsinskaya Fizika","volume":"89 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Meditsinskaya Fizika","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52775/1810-200x-2022-96-4-56-63","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: In the conditions of a constant increase in the number of computer vision algorithms developed based on artificial intelligence (AI) for medical diagnostics, it becomes necessary to determine criteria for deciding whether their practical application for mass preventive studies of the population is appropriate. Materials and methods: The study with the participation of several radiologists was conducted on a “Web platform for evaluating radiological studies” on a marked data set containing digital radiographs and fluorograms in an anterior direct projection. On the same data set, using the “Versioning Testing Platform”, responses were obtained from two commercial AI-based computer vision algorithms developed for the analysis of digital radiographs. Evaluation of the results obtained from doctors and algorithms (binary, in terms of “with pathology” and “without pathology”) was carried out using ROC analysis. For the threshold value calculated by the Yuden method, the following metrics were determined: sensitivity, specificity and accuracy. Results: diagnostic accuracy metrics were calculated for the average assessment of radiologists and AI-based computer vision algorithms when searching for pathological changes on chest X-rays in anterior direct projection according to ROC analysis. The average values of diagnostic accuracy indicators of radiologists exceeded the indicators of AI services. Conclusions: when deciding on the implementation of AI-based computer vision algorithms for preventive research, One should be guided by the metrics of diagnostic accuracy of a particular algorithm and use the average result of doctors in solving this diagnostic problem as the target values of metrics.
计算机视觉在预防研究中的适用性标准——以胸部x线和x线摄影为例
目的:在基于人工智能(AI)开发的用于医学诊断的计算机视觉算法数量不断增加的情况下,有必要确定标准,以确定它们在人群大规模预防研究中的实际应用是否合适。材料和方法:本研究由几位放射科医生参与,在一个“评估放射学研究的网络平台”上进行,在一个标记的数据集上进行,该数据集包含前路直接投影的数字x线照片和荧光图。在相同的数据集上,使用“版本控制测试平台”,从两种商业的基于人工智能的计算机视觉算法中获得响应,这些算法是为分析数字射线照片而开发的。使用ROC分析对从医生和算法获得的结果(“有病理”和“无病理”的二元)进行评估。对于Yuden法计算的阈值,确定以下指标:敏感性、特异性和准确性。结果:根据ROC分析计算放射科医师和基于人工智能的计算机视觉算法在搜索胸部x射线前路直接投影的病理变化时的平均评估的诊断准确性指标。放射科医师诊断准确率指标平均值超过人工智能服务指标。结论:在决定实施基于人工智能的计算机视觉算法进行预防研究时,应以特定算法的诊断准确性指标为指导,并以医生解决该诊断问题的平均结果作为指标的目标值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书