{"title":"Spectral Distribution of Neutron Dose in Phantom","authors":"A. M. Sayed, N. A. Al-Liabi","doi":"10.1080/10256018408623395","DOIUrl":null,"url":null,"abstract":"Thermal, intermediate and fast neutron fluxes from Pu-Be neutron source has been measured inside a tissue-equivalent phantom using solid state nuclear track detectors. The fluence-dose conversion factors as well as related quality factors were used for absorbed dose and dose equivalent calculations. The experimental results were found to be in fair agreement with theoretical calculations. The contribution of thermal and intermediate neutron dose is lower relative to that for fast neutrons. Unter Verwendung von Festkorper-Kernspurdetektoren wurden die Flusse von thermischen, mittelschnellen und schnellen Neutronen von einer Pu-Be-Neutronenquelle in einem gewebeaquivalenten Phantom gemessen. Fur die Berechnung der absorbierten Dosis und des Dosis-Aquivalents wurden Fluβ-Dosis-Umrechnungsfaktoren und entsprechende Qualitatsfaktoren angewandt. Es wurde festgestellt, daβ die Versuchsergebnisse verhaltnismaβig gut mit den theoretischen Berechnungen ubereinstimmten. Der Beitrag der thermischen und der mittelschn...","PeriodicalId":280283,"journal":{"name":"November 1984","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1984-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"November 1984","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/10256018408623395","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
Thermal, intermediate and fast neutron fluxes from Pu-Be neutron source has been measured inside a tissue-equivalent phantom using solid state nuclear track detectors. The fluence-dose conversion factors as well as related quality factors were used for absorbed dose and dose equivalent calculations. The experimental results were found to be in fair agreement with theoretical calculations. The contribution of thermal and intermediate neutron dose is lower relative to that for fast neutrons. Unter Verwendung von Festkorper-Kernspurdetektoren wurden die Flusse von thermischen, mittelschnellen und schnellen Neutronen von einer Pu-Be-Neutronenquelle in einem gewebeaquivalenten Phantom gemessen. Fur die Berechnung der absorbierten Dosis und des Dosis-Aquivalents wurden Fluβ-Dosis-Umrechnungsfaktoren und entsprechende Qualitatsfaktoren angewandt. Es wurde festgestellt, daβ die Versuchsergebnisse verhaltnismaβig gut mit den theoretischen Berechnungen ubereinstimmten. Der Beitrag der thermischen und der mittelschn...