In Situ Degradation Monitoring Methods during Lifetime Testing of Power Electronic Modules

A. Schiffmacher, D. Strahringer, Shreyas Malasani, J. Wilde, Carsten Kempiak, A. Lindemann
{"title":"In Situ Degradation Monitoring Methods during Lifetime Testing of Power Electronic Modules","authors":"A. Schiffmacher, D. Strahringer, Shreyas Malasani, J. Wilde, Carsten Kempiak, A. Lindemann","doi":"10.1109/ECTC32696.2021.00149","DOIUrl":null,"url":null,"abstract":"Within the scope of this work three in-situ degradation monitoring methods are presented. The methods are suitable for the detection of degradations in power electronic modules during active power cycling test without interrupting the test itself. A comparison of the results is illustrated by conducting all three techniques during the lifetime testing of a power electronic module at the same time. In sum, electrical, electrothermal, thermal and thermomechanical parameters were evaluated. From the observations, we conclude that the primary failure mechanism of a novel die-top interconnect technology for power modules is the crack propagation in the Al-metallisation of the semiconductor. Cross-sectional images of the samples were prepared to confirm the previously given evidence of the failure. Furthermore a lifetime model was established for this assembly technology. Finally, a comparison of the advantages and limitations of the conducted degradation monitoring techniques will be presented.","PeriodicalId":351817,"journal":{"name":"2021 IEEE 71st Electronic Components and Technology Conference (ECTC)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE 71st Electronic Components and Technology Conference (ECTC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECTC32696.2021.00149","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Within the scope of this work three in-situ degradation monitoring methods are presented. The methods are suitable for the detection of degradations in power electronic modules during active power cycling test without interrupting the test itself. A comparison of the results is illustrated by conducting all three techniques during the lifetime testing of a power electronic module at the same time. In sum, electrical, electrothermal, thermal and thermomechanical parameters were evaluated. From the observations, we conclude that the primary failure mechanism of a novel die-top interconnect technology for power modules is the crack propagation in the Al-metallisation of the semiconductor. Cross-sectional images of the samples were prepared to confirm the previously given evidence of the failure. Furthermore a lifetime model was established for this assembly technology. Finally, a comparison of the advantages and limitations of the conducted degradation monitoring techniques will be presented.
电力电子模块寿命试验中的原位劣化监测方法
在这项工作的范围内,提出了三种原位退化监测方法。该方法适用于电力有功循环试验中电力电子模块退化的检测,而不中断试验本身。通过在电力电子模块的寿命测试中同时进行这三种技术,说明了结果的比较。总之,电学、电热、热学和热力学参数进行了评估。从观察中,我们得出结论,新型电源模块模顶互连技术的主要失效机制是半导体铝金属化中的裂纹扩展。准备了样品的横截面图像,以确认先前给出的失败证据。在此基础上,建立了该装配工艺的寿命模型。最后,比较了传导降解监测技术的优点和局限性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信