{"title":"Partial Discharge Detection in an Aeronautical Power Cable","authors":"M. Karadjian, N. Imbert, C. Munier, M. Kirkpatrick, E. Odic","doi":"10.2514/6.2018-5033","DOIUrl":null,"url":null,"abstract":"The augmentation of voltage levels in aeronautical power networks may provoke the phenomena of electrical discharges. It is shown that PDs occurred at the cable periphery in proximity to a grounded conductor for voltages ranging from 750 V to 2000 V for gas pressure from 100 mbar up to atmospheric pressure. At higher voltage, internal PDs were found to take place between the conductor strands and the inner walls of the cable insulation. This discharge localization was confirmed by the dependence of PDIV and RPDIV values on the imposed gas pressure and by electrostatic calculations taking into account the gas breakdown voltages from the Paschen curve. The influence of thermal aging on PD activity was also investigated. Thermal aging was found to not change the external discharge inception voltage but to affect internal discharges.","PeriodicalId":276296,"journal":{"name":"2018 AIAA/IEEE Electric Aircraft Technologies Symposium (EATS)","volume":"3 4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 AIAA/IEEE Electric Aircraft Technologies Symposium (EATS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2514/6.2018-5033","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The augmentation of voltage levels in aeronautical power networks may provoke the phenomena of electrical discharges. It is shown that PDs occurred at the cable periphery in proximity to a grounded conductor for voltages ranging from 750 V to 2000 V for gas pressure from 100 mbar up to atmospheric pressure. At higher voltage, internal PDs were found to take place between the conductor strands and the inner walls of the cable insulation. This discharge localization was confirmed by the dependence of PDIV and RPDIV values on the imposed gas pressure and by electrostatic calculations taking into account the gas breakdown voltages from the Paschen curve. The influence of thermal aging on PD activity was also investigated. Thermal aging was found to not change the external discharge inception voltage but to affect internal discharges.
航空电力电缆局部放电检测
航空电网中电压等级的升高可能引起放电现象。结果表明,电压从750 V到2000 V,气体压力从100毫巴到大气压,在靠近接地导体的电缆外围发生脉冲放电。在较高的电压下,发现内部pd发生在导体股和电缆绝缘内壁之间。PDIV和RPDIV值对施加的气体压力的依赖性以及考虑Paschen曲线的气体击穿电压的静电计算证实了这种放电定位。研究了热老化对PD活性的影响。发现热老化不改变外部放电起始电压,但影响内部放电。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信