The Difference of Potassium Level in Stage 5 Kidney Chronic Disease Patients Whose Using New and Re-use Hemodialyzer in RSD dr. Soebandi Jember

Yuli Hermansyah, Dinda Ayu Wanodya Supriatiningsih, Bagus Hermansyah
{"title":"The Difference of Potassium Level in Stage 5 Kidney Chronic Disease Patients Whose Using New and Re-use Hemodialyzer in RSD dr. Soebandi Jember","authors":"Yuli Hermansyah, Dinda Ayu Wanodya Supriatiningsih, Bagus Hermansyah","doi":"10.19184/ams.v5i3.9540","DOIUrl":null,"url":null,"abstract":"Stage 5 chronic kidney disease (CKD) is a condition where the renal function decrease, marked by the GFR value < 15/ml/minute/1,73 m2 with or without kidney damage history for 3 months or more that needs kidney replacement therapy, including hemodialysis. In Indonesia, hemodialysis was chosen for 82% from all the cases that needs kidney replacement therapy. However, the cost for hemodialysis therapy is considered as too expensive and burdens The National Health Insurance, Badan Penyelenggara Jaminan Sosial (BPJS), allowing the reuse of hemodialyzer as an alternative for cost-effectiveness. Re-use hemodialyzer is a term for using the same hemodialyzer for the same patient but on different therapy session. The main purpose of this research is to investigate the difference of Potassium level in stage 5 chronic kidney disease patients whose using new and re-use hemodialyzer in RSD dr. Soebandi Jember. This research used quasi experimental design by using blood sample that will be measured for the potassium level after using new hemodialyzer and re-use hemodialyzer for the 4th time in Hemodialysis Installation of RSD dr. Soebandi Jember on December 2018. Total sample of 19 patients chosen using inclusion and exclusion criteria. Collected data were analyzed using paired t-test. The result of statistical test shows that there is no significance potassium level difference in stage 5 chronic kidney disease whose using new and re-use hemodialyzer for the 4th time (p=0,094). The effectivity of hemodialyzer that still has a good condition and hemodialysis therapy that has been done in accordance with the procedure until the 4th reuse is the main factor of this result. \n  \nKeywords: CKD, potassium, re-use hemodialyzer","PeriodicalId":246242,"journal":{"name":"Journal of Agromedicine and Medical Sciences","volume":"140 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Agromedicine and Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.19184/ams.v5i3.9540","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Stage 5 chronic kidney disease (CKD) is a condition where the renal function decrease, marked by the GFR value < 15/ml/minute/1,73 m2 with or without kidney damage history for 3 months or more that needs kidney replacement therapy, including hemodialysis. In Indonesia, hemodialysis was chosen for 82% from all the cases that needs kidney replacement therapy. However, the cost for hemodialysis therapy is considered as too expensive and burdens The National Health Insurance, Badan Penyelenggara Jaminan Sosial (BPJS), allowing the reuse of hemodialyzer as an alternative for cost-effectiveness. Re-use hemodialyzer is a term for using the same hemodialyzer for the same patient but on different therapy session. The main purpose of this research is to investigate the difference of Potassium level in stage 5 chronic kidney disease patients whose using new and re-use hemodialyzer in RSD dr. Soebandi Jember. This research used quasi experimental design by using blood sample that will be measured for the potassium level after using new hemodialyzer and re-use hemodialyzer for the 4th time in Hemodialysis Installation of RSD dr. Soebandi Jember on December 2018. Total sample of 19 patients chosen using inclusion and exclusion criteria. Collected data were analyzed using paired t-test. The result of statistical test shows that there is no significance potassium level difference in stage 5 chronic kidney disease whose using new and re-use hemodialyzer for the 4th time (p=0,094). The effectivity of hemodialyzer that still has a good condition and hemodialysis therapy that has been done in accordance with the procedure until the 4th reuse is the main factor of this result.   Keywords: CKD, potassium, re-use hemodialyzer
肾慢性疾病5期患者在RSD中使用新型和重复使用血液透析器时钾水平的差异
5期慢性肾脏疾病(CKD)是指肾功能下降,以GFR < 15/ml/min /1,73 m2为标志,伴有或无肾损害病史3个月或以上,需要肾脏替代治疗,包括血液透析。在印度尼西亚,82%需要肾脏替代治疗的病例选择了血液透析。然而,血液透析治疗的费用被认为过于昂贵,给国民健康保险(Badan Penyelenggara Jaminan social, BPJS)造成负担,允许重新使用血液透析器作为一种具有成本效益的替代方法。重复使用血液透析器是指对同一患者在不同疗程中使用相同的血液透析器。本研究的主要目的是探讨在RSD中使用新型和重复使用血液透析器的5期慢性肾脏疾病患者钾水平的差异。本研究采用准实验设计,于2018年12月在RSD博士Soebandi Jember的血液透析装置中使用新血液透析器和第4次使用血液透析器后测量血液中的钾水平。采用纳入和排除标准选取19例患者。收集的资料采用配对t检验进行分析。统计检验结果显示,第4次使用新血液透析器和第4次重复使用血液透析器的5期慢性肾病患者钾水平差异无统计学意义(p= 0.094)。血液透析器保持良好状态的有效性和按照程序进行的血液透析治疗直到第4次重复使用是影响这一结果的主要因素。关键词:慢性肾病,钾,再利用血液透析器
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信