{"title":"Removable Overdenture versus fixed Bridge fabricated on all-on-4 implants using CAD/CAM technology (Strain Gauge Analysis)","authors":"Karim Osama Kamal Elnabarawy, Ahmed El Damarisy, Marwa, Kothayer, F. Rizk, M. Sabet","doi":"10.46624/bjmhr.2021.v8.i12.004","DOIUrl":null,"url":null,"abstract":"Assessing the effects on maxilla when using fixed vs. removable prosthesis on All-On-4® protocol. This in-vitro study was conducted to compare stresses induced on distal implants in All-On-4® concept, between digitally constructed removable overdenture and fixed bridge, using strain gauge analysis. Four dummy implants were placed in their designed locations according to the All-On-4® concept; in 3D printed completely edentulous maxillary acrylic cast. Multiunit abutments were secured to the implants. Two groups were defined: Group A: in which the framework was cemented to the four titanium copings over the implants (Fixed bridge). Group B: in which the same framework was picked up after relief was done and then seated on the ball attachments (Removable overdenture). Stresses were measured using strain gauges installed in their designed sites in the 3D printed cast. Loads of 100N were applied in a vertical and oblique direction on the right molar area. Paired t test was used to compare between two different load directions within the same group and unpaired t test was used to compare between different groups. P-value ? 0.05 was statistically significant. Group A with vertical loads (532±9.2) and oblique loads (464±40.3) showed significantly higher stresses on the supporting structures of the distal implants than group B with vertical loads (64 ±7.75) and oblique loads (41.5±2.42). Within group A, higher microstrains were recorded on the distal implants in the loaded side in case of applying vertical loads (532±9.2) than in case of oblique loads (464±40.3). Also, lower microstrains were recorded in the unloaded side in case of vertical loads (21.5±2.42) than in case of oblique loads (43±2.58). Within group B, higher microstrains were recorded in the loaded side in case of applying vertical loads (64±7.75), than in case of oblique loads (41.5±2.42). Also, lower microstrains were recorded in the unloaded side in case of vertical loads (10.5±1.58) than in case of obliq","PeriodicalId":417873,"journal":{"name":"British Journal of Medical and Health Research","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"British Journal of Medical and Health Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46624/bjmhr.2021.v8.i12.004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Assessing the effects on maxilla when using fixed vs. removable prosthesis on All-On-4® protocol. This in-vitro study was conducted to compare stresses induced on distal implants in All-On-4® concept, between digitally constructed removable overdenture and fixed bridge, using strain gauge analysis. Four dummy implants were placed in their designed locations according to the All-On-4® concept; in 3D printed completely edentulous maxillary acrylic cast. Multiunit abutments were secured to the implants. Two groups were defined: Group A: in which the framework was cemented to the four titanium copings over the implants (Fixed bridge). Group B: in which the same framework was picked up after relief was done and then seated on the ball attachments (Removable overdenture). Stresses were measured using strain gauges installed in their designed sites in the 3D printed cast. Loads of 100N were applied in a vertical and oblique direction on the right molar area. Paired t test was used to compare between two different load directions within the same group and unpaired t test was used to compare between different groups. P-value ? 0.05 was statistically significant. Group A with vertical loads (532±9.2) and oblique loads (464±40.3) showed significantly higher stresses on the supporting structures of the distal implants than group B with vertical loads (64 ±7.75) and oblique loads (41.5±2.42). Within group A, higher microstrains were recorded on the distal implants in the loaded side in case of applying vertical loads (532±9.2) than in case of oblique loads (464±40.3). Also, lower microstrains were recorded in the unloaded side in case of vertical loads (21.5±2.42) than in case of oblique loads (43±2.58). Within group B, higher microstrains were recorded in the loaded side in case of applying vertical loads (64±7.75), than in case of oblique loads (41.5±2.42). Also, lower microstrains were recorded in the unloaded side in case of vertical loads (10.5±1.58) than in case of obliq