Removable Overdenture versus fixed Bridge fabricated on all-on-4 implants using CAD/CAM technology (Strain Gauge Analysis)

Karim Osama Kamal Elnabarawy, Ahmed El Damarisy, Marwa, Kothayer, F. Rizk, M. Sabet
{"title":"Removable Overdenture versus fixed Bridge fabricated on all-on-4 implants using CAD/CAM technology (Strain Gauge Analysis)","authors":"Karim Osama Kamal Elnabarawy, Ahmed El Damarisy, Marwa, Kothayer, F. Rizk, M. Sabet","doi":"10.46624/bjmhr.2021.v8.i12.004","DOIUrl":null,"url":null,"abstract":"Assessing the effects on maxilla when using fixed vs. removable prosthesis on All-On-4® protocol. This in-vitro study was conducted to compare stresses induced on distal implants in All-On-4® concept, between digitally constructed removable overdenture and fixed bridge, using strain gauge analysis. Four dummy implants were placed in their designed locations according to the All-On-4® concept; in 3D printed completely edentulous maxillary acrylic cast. Multiunit abutments were secured to the implants. Two groups were defined: Group A: in which the framework was cemented to the four titanium copings over the implants (Fixed bridge). Group B: in which the same framework was picked up after relief was done and then seated on the ball attachments (Removable overdenture). Stresses were measured using strain gauges installed in their designed sites in the 3D printed cast. Loads of 100N were applied in a vertical and oblique direction on the right molar area. Paired t test was used to compare between two different load directions within the same group and unpaired t test was used to compare between different groups. P-value ? 0.05 was statistically significant. Group A with vertical loads (532±9.2) and oblique loads (464±40.3) showed significantly higher stresses on the supporting structures of the distal implants than group B with vertical loads (64 ±7.75) and oblique loads (41.5±2.42). Within group A, higher microstrains were recorded on the distal implants in the loaded side in case of applying vertical loads (532±9.2) than in case of oblique loads (464±40.3). Also, lower microstrains were recorded in the unloaded side in case of vertical loads (21.5±2.42) than in case of oblique loads (43±2.58). Within group B, higher microstrains were recorded in the loaded side in case of applying vertical loads (64±7.75), than in case of oblique loads (41.5±2.42). Also, lower microstrains were recorded in the unloaded side in case of vertical loads (10.5±1.58) than in case of obliq","PeriodicalId":417873,"journal":{"name":"British Journal of Medical and Health Research","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"British Journal of Medical and Health Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46624/bjmhr.2021.v8.i12.004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Assessing the effects on maxilla when using fixed vs. removable prosthesis on All-On-4® protocol. This in-vitro study was conducted to compare stresses induced on distal implants in All-On-4® concept, between digitally constructed removable overdenture and fixed bridge, using strain gauge analysis. Four dummy implants were placed in their designed locations according to the All-On-4® concept; in 3D printed completely edentulous maxillary acrylic cast. Multiunit abutments were secured to the implants. Two groups were defined: Group A: in which the framework was cemented to the four titanium copings over the implants (Fixed bridge). Group B: in which the same framework was picked up after relief was done and then seated on the ball attachments (Removable overdenture). Stresses were measured using strain gauges installed in their designed sites in the 3D printed cast. Loads of 100N were applied in a vertical and oblique direction on the right molar area. Paired t test was used to compare between two different load directions within the same group and unpaired t test was used to compare between different groups. P-value ? 0.05 was statistically significant. Group A with vertical loads (532±9.2) and oblique loads (464±40.3) showed significantly higher stresses on the supporting structures of the distal implants than group B with vertical loads (64 ±7.75) and oblique loads (41.5±2.42). Within group A, higher microstrains were recorded on the distal implants in the loaded side in case of applying vertical loads (532±9.2) than in case of oblique loads (464±40.3). Also, lower microstrains were recorded in the unloaded side in case of vertical loads (21.5±2.42) than in case of oblique loads (43±2.58). Within group B, higher microstrains were recorded in the loaded side in case of applying vertical loads (64±7.75), than in case of oblique loads (41.5±2.42). Also, lower microstrains were recorded in the unloaded side in case of vertical loads (10.5±1.58) than in case of obliq
使用CAD/CAM技术(应变计分析)在all-on-4种植体上制作可移动覆盖义齿与固定桥
评估在All-On-4®协议下使用固定假体和可移动假体对上颌骨的影响。本体外研究采用应变计分析方法,比较了All-On-4®概念中数字构建的可移动覆盖义齿和固定桥在远端种植体上引起的应力。根据All-On-4®概念,将四个假体植入其设计位置;在3D打印完全无牙上颌丙烯酸铸件。多单元基台固定在种植体上。分为两组:A组:将框架与种植体上方的四个钛覆盖物(固定桥)粘合。B组:松解后取同一框架,固定于球形附着体(活动覆盖义齿)上。使用安装在3D打印铸件设计位置的应变片测量应力。在右磨牙区垂直和斜方向分别施加100N的载荷。同一组内两个不同负荷方向间比较采用配对t检验,不同组间比较采用非配对t检验。假定值吗?0.05有统计学意义。A组垂直载荷(532±9.2)和斜载荷(464±40.3)对远端种植体支撑结构的应力显著高于B组垂直载荷(64±7.75)和斜载荷(41.5±2.42)。在A组中,施加垂直载荷时远端种植体的微应变(532±9.2)高于施加斜载荷时的微应变(464±40.3)。竖向荷载作用下的微应变(21.5±2.42)小于斜荷载作用下的微应变(43±2.58)。在B组中,施加垂直载荷时,受累侧微应变(64±7.75)高于施加斜载荷时(41.5±2.42)。竖向荷载作用下,卸载侧微应变(10.5±1.58)小于斜向荷载作用下
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书