{"title":"Chemical sensor systems using xerogels and CMOS detectors","authors":"M. Davenport, A. Titus, E. Tehan, F. Bright","doi":"10.1109/ICSENS.2003.1279154","DOIUrl":null,"url":null,"abstract":"We have developed a chemical sensing platform based on xerogel thin film sensor elements coupled with CMOS detectors. We demonstrate the operation of the sensing platform as a simple oxygen sensor. The quenchometric operation of the oxygen sensor coupled with CMOS detectors is compared to standard laboratory detection systems (CCD and PMT). The Stern-Volmer quenching constant (k/sub SV/) is used as a comparative measure of the operation of each of these systems. In our initial experiments all three systems yielded a k/sub SV/ between 0.042 and 0.049 O/sub 2/%/sup -1/. The xerogel sensor elements have demonstrated satisfactory reusability and stability over a period of more than six months. The CMOS detectors consume less than 0.1% of the power required for the PMT or CCD detectors, and are an attractive platform for array processing and portable applications.","PeriodicalId":369277,"journal":{"name":"Proceedings of IEEE Sensors 2003 (IEEE Cat. No.03CH37498)","volume":"123 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-10-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of IEEE Sensors 2003 (IEEE Cat. No.03CH37498)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENS.2003.1279154","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
We have developed a chemical sensing platform based on xerogel thin film sensor elements coupled with CMOS detectors. We demonstrate the operation of the sensing platform as a simple oxygen sensor. The quenchometric operation of the oxygen sensor coupled with CMOS detectors is compared to standard laboratory detection systems (CCD and PMT). The Stern-Volmer quenching constant (k/sub SV/) is used as a comparative measure of the operation of each of these systems. In our initial experiments all three systems yielded a k/sub SV/ between 0.042 and 0.049 O/sub 2/%/sup -1/. The xerogel sensor elements have demonstrated satisfactory reusability and stability over a period of more than six months. The CMOS detectors consume less than 0.1% of the power required for the PMT or CCD detectors, and are an attractive platform for array processing and portable applications.