Feedback linearization with integrator of DCDC buck converter taking into account parasitic elements

Miklós Csizmadia, M. Kuczmann
{"title":"Feedback linearization with integrator of DCDC buck converter taking into account parasitic elements","authors":"Miklós Csizmadia, M. Kuczmann","doi":"10.1109/PEMC48073.2021.9432632","DOIUrl":null,"url":null,"abstract":"This paper presents the feedback linearization based control of DC/DC buck converter, the output voltage controlled. Also, the presence of parasitic elements are not studied in detail in a previous article, therefore the applied state space model are taking into account of those. The high slew rate of the controller cause inrush current during start-up, which have been examined and reduced. The linearized system has been investigated with linear quadratic regulator (LQR) through an example and simulated via Matlab.","PeriodicalId":349940,"journal":{"name":"2021 IEEE 19th International Power Electronics and Motion Control Conference (PEMC)","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-04-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE 19th International Power Electronics and Motion Control Conference (PEMC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEMC48073.2021.9432632","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

This paper presents the feedback linearization based control of DC/DC buck converter, the output voltage controlled. Also, the presence of parasitic elements are not studied in detail in a previous article, therefore the applied state space model are taking into account of those. The high slew rate of the controller cause inrush current during start-up, which have been examined and reduced. The linearized system has been investigated with linear quadratic regulator (LQR) through an example and simulated via Matlab.
考虑寄生元件的DCDC降压变换器积分器反馈线性化
本文提出了基于反馈线性化的DC/DC降压变换器的控制方法,控制输出电压。此外,在前一篇文章中没有详细研究寄生元素的存在,因此所应用的状态空间模型将考虑这些因素。控制器的高转换率在启动过程中会产生浪涌电流,经过检测并减小了浪涌电流。通过实例研究了线性二次型调节器(LQR)对线性化系统的影响,并进行了Matlab仿真。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信