Effect of a patient educational video on visual field test reliability

Hsin Yi Lee, N. Ramli, Nurul Akma Saharuddin, Hanim Syed Yaziz Siti Faeza, P. Ong
{"title":"Effect of a patient educational video on visual field test reliability","authors":"Hsin Yi Lee, N. Ramli, Nurul Akma Saharuddin, Hanim Syed Yaziz Siti Faeza, P. Ong","doi":"10.35119/myjo.v4i2.249","DOIUrl":null,"url":null,"abstract":"Purpose: Standard automated perimetry (SAP) is the gold standard for detecting and monitoring visual field (VF) defects in glaucoma, but frequent re-testing due to unreliable results increase the burden on this frequently used service. This study aims to assess the reliability of the Humphrey visual field (HVF) test in glaucoma-suspect patients with no previous SAP experience and to determine the effect of a VF test educational video on reliability.Study design: The study was conducted as a full cycle audit.Methods: The audit cycle was carried out in four phases: pre-intervention audit, intervention, monitoring, and post-intervention audit. The pre-intervention audit was carried out from January 2020 to May 2020 and the post-intervention audit was carried out from September 2020 to December 2020. The intervention was in the form of a VF test educational video. A post-video assessment pertaining to the contents of the video was given to patients in the intervention group to complete after they watched the video. The results were then tabulated and analysed.Results: The pre-intervention audit showed that only 66.7% of glaucoma-suspect patients with no previous SAP experience had reliable HVF tests. Post-intervention, HVF reliability improved to 87.5% of patients. Based on the reliability parameters, the main reason for the HVF test being classified as unreliable in both the pre- and post-intervention was fixation loss greater than 20% in 36 (90%) and 11 (73.3%) patients, respectively. There were 76.9% of patients with unreliable fields who had < 4 correct answers on the post-video assessment; all patients who had > 4 correct answers had reliable HVF results.Conclusion: HVF reliability performance in glaucoma-suspect patients improved with the introduction of a pre-test educational video. It is a simple and inexpensive method which may reduce the need for repeat HVF tests for those with unreliable tests.","PeriodicalId":405983,"journal":{"name":"Malaysian Journal of Ophthalmology","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Malaysian Journal of Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35119/myjo.v4i2.249","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Standard automated perimetry (SAP) is the gold standard for detecting and monitoring visual field (VF) defects in glaucoma, but frequent re-testing due to unreliable results increase the burden on this frequently used service. This study aims to assess the reliability of the Humphrey visual field (HVF) test in glaucoma-suspect patients with no previous SAP experience and to determine the effect of a VF test educational video on reliability.Study design: The study was conducted as a full cycle audit.Methods: The audit cycle was carried out in four phases: pre-intervention audit, intervention, monitoring, and post-intervention audit. The pre-intervention audit was carried out from January 2020 to May 2020 and the post-intervention audit was carried out from September 2020 to December 2020. The intervention was in the form of a VF test educational video. A post-video assessment pertaining to the contents of the video was given to patients in the intervention group to complete after they watched the video. The results were then tabulated and analysed.Results: The pre-intervention audit showed that only 66.7% of glaucoma-suspect patients with no previous SAP experience had reliable HVF tests. Post-intervention, HVF reliability improved to 87.5% of patients. Based on the reliability parameters, the main reason for the HVF test being classified as unreliable in both the pre- and post-intervention was fixation loss greater than 20% in 36 (90%) and 11 (73.3%) patients, respectively. There were 76.9% of patients with unreliable fields who had < 4 correct answers on the post-video assessment; all patients who had > 4 correct answers had reliable HVF results.Conclusion: HVF reliability performance in glaucoma-suspect patients improved with the introduction of a pre-test educational video. It is a simple and inexpensive method which may reduce the need for repeat HVF tests for those with unreliable tests.
患者教育录像对视野测试信度的影响
目的:标准自动视距检查(SAP)是检测和监测青光眼视野缺陷的金标准,但由于结果不可靠而频繁的重新检测增加了这项常用服务的负担。本研究旨在评估汉弗莱视野(HVF)测试在青光眼疑似患者中没有SAP经验的可靠性,并确定VF测试教育视频对可靠性的影响。研究设计:本研究采用全周期审核。方法:审计周期分为干预前审计、干预、监测和干预后审计四个阶段。干预前审计于2020年1月至2020年5月进行,干预后审计于2020年9月至2020年12月进行。干预的形式是VF测试教育视频。与视频内容相关的视频后评估被给予干预组的患者,让他们在看完视频后完成。然后将结果制成表格并进行分析。结果:干预前审计显示,在没有SAP经历的疑似青光眼患者中,仅有66.7%的患者有可靠的HVF测试。干预后,HVF的可靠性提高到87.5%。从信度参数来看,干预前和干预后HVF测试不可靠的主要原因是固定损失大于20%,分别为36例(90%)和11例(73.3%)。76.9%的不可靠领域患者在视频后评估中正确答案< 4;正确答案> 4的患者均有可靠的HVF结果。结论:在青光眼疑似患者中,HVF的可靠性表现随着测试前教育视频的引入而改善。这是一种简单而廉价的方法,可以减少对那些检测不可靠的人进行重复HVF检测的需要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信