{"title":"THE INFLUENCE OF BUILDING ENVELOPES TOWARDS INDOOR CLASSROOM TEMPERATURE (Case: BINUS Alam Sutera Campus)","authors":"Rivanus Dewanto","doi":"10.25105/LIVAS.V4I1.4693","DOIUrl":null,"url":null,"abstract":"ABSTRACTThe building façade of BINUS Alam Sutera campus is designed with wall variations of building envelope both in terms of material use and of openings volume. These conditions encourage the researcher to observe how much the indoor temperature difference in the classroom is correlated to the wall completion of the building envelope. The method used was by measuring indoor and outdoor temperatures at the same time periods (morning, midday, and afternoon) from the classrooms in different floors. The result of the study reveals that indoor temperature increases relatively towards the sun orientation of north-northeast and of west-southwest. The building envelope with precast concrete and window-wall affects indoor temperature relatively higher in the morning and lower in the afternoon. Whereas the building envelope with precast concrete of dead-glass variation affects indoor temperature relatively lower in the morning yet higher in the afternoon.Keywords: Building envelopes, indoor temperature, classrooms","PeriodicalId":133023,"journal":{"name":"International Journal on Livable Space","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal on Livable Space","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25105/LIVAS.V4I1.4693","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

ABSTRACTThe building façade of BINUS Alam Sutera campus is designed with wall variations of building envelope both in terms of material use and of openings volume. These conditions encourage the researcher to observe how much the indoor temperature difference in the classroom is correlated to the wall completion of the building envelope. The method used was by measuring indoor and outdoor temperatures at the same time periods (morning, midday, and afternoon) from the classrooms in different floors. The result of the study reveals that indoor temperature increases relatively towards the sun orientation of north-northeast and of west-southwest. The building envelope with precast concrete and window-wall affects indoor temperature relatively higher in the morning and lower in the afternoon. Whereas the building envelope with precast concrete of dead-glass variation affects indoor temperature relatively lower in the morning yet higher in the afternoon.Keywords: Building envelopes, indoor temperature, classrooms
建筑围护结构对教室室内温度的影响(以BINUS Alam Sutera校区为例)
摘要BINUS Alam Sutera校区的建筑立面在材料使用和开口体积方面都采用了建筑围护结构的墙体变化设计。这些条件促使研究人员观察教室室内温差与建筑围护结构的墙体完工程度有多大关系。所使用的方法是通过测量不同楼层教室在同一时间段(上午、中午和下午)的室内和室外温度。研究结果表明,室内温度在太阳的北-东北方向和西-西南方向相对升高。预制混凝土和窗墙的围护结构对室内温度的影响上午较高,下午较低。而采用死玻璃变化的预制混凝土围护结构对室内温度的影响是上午较低,下午较高。关键词:建筑围护结构,室内温度,教室
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信