O. Shimada, S. Kusumi, H. Mekaru, N. Sato, M. Shimizu, M. Yamashita, T. Hattori
{"title":"Fabrication of Spiral Micro-Coil Utilizing LIGA Process","authors":"O. Shimada, S. Kusumi, H. Mekaru, N. Sato, M. Shimizu, M. Yamashita, T. Hattori","doi":"10.1299/JSMEA.49.74","DOIUrl":null,"url":null,"abstract":"We developed a method for fabricating a three-dimensional spiral micro-inductor with high inductance using the LIGA process. The spiral inductor created had a diameter of 0.5mm, and a length of 1mm. The width of the spiral line was 10µm, the pitch was 20µm, and the number of turns was 15. It was made of plated copper. The master was a brass round bar coated with PMMA resist. Deep X-ray lithography was employed to fabricate a master for a metallic mold at the NewSUBARU synchrotron radiation facility, University of Hyogo. The inductor core was made of resin by injection molding. It has a spiral micro flute on the surface. We chose the worm injection molding technique in order to avoid the parting line across the spiral line. The worm injection molding was the method─for demolding the work such as that used in loosening a screw.","PeriodicalId":170519,"journal":{"name":"Jsme International Journal Series A-solid Mechanics and Material Engineering","volume":"202 ","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jsme International Journal Series A-solid Mechanics and Material Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1299/JSMEA.49.74","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9
Abstract
We developed a method for fabricating a three-dimensional spiral micro-inductor with high inductance using the LIGA process. The spiral inductor created had a diameter of 0.5mm, and a length of 1mm. The width of the spiral line was 10µm, the pitch was 20µm, and the number of turns was 15. It was made of plated copper. The master was a brass round bar coated with PMMA resist. Deep X-ray lithography was employed to fabricate a master for a metallic mold at the NewSUBARU synchrotron radiation facility, University of Hyogo. The inductor core was made of resin by injection molding. It has a spiral micro flute on the surface. We chose the worm injection molding technique in order to avoid the parting line across the spiral line. The worm injection molding was the method─for demolding the work such as that used in loosening a screw.