A 4.7T/11.1T NMR compliant wirelessly programmable implant for bio-artificial pancreas in vivo monitoring

W. Turner, R. Bashirullah
{"title":"A 4.7T/11.1T NMR compliant wirelessly programmable implant for bio-artificial pancreas in vivo monitoring","authors":"W. Turner, R. Bashirullah","doi":"10.1109/VLSIC.2014.6858410","DOIUrl":null,"url":null,"abstract":"This paper presents the design, implementation, and nuclear magnetic resonance (NMR) measurements of a wireless, magnetic compliant, implant that increases the signal sensitivity of NMR images by 3.8dB and 2.6dB in 4.7T and 11.1T magnetic field strengths respectively. The device supports sustained reliable operation through a strongly coupled resonance wireless powering scheme in addition to improving high-resolution image SNR up to 73% within the region of interest.","PeriodicalId":381216,"journal":{"name":"2014 Symposium on VLSI Circuits Digest of Technical Papers","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 Symposium on VLSI Circuits Digest of Technical Papers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/VLSIC.2014.6858410","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper presents the design, implementation, and nuclear magnetic resonance (NMR) measurements of a wireless, magnetic compliant, implant that increases the signal sensitivity of NMR images by 3.8dB and 2.6dB in 4.7T and 11.1T magnetic field strengths respectively. The device supports sustained reliable operation through a strongly coupled resonance wireless powering scheme in addition to improving high-resolution image SNR up to 73% within the region of interest.
4.7T/11.1T核磁共振兼容无线可编程植入物用于生物人工胰腺体内监测
本文介绍了一种无线、磁兼容植入物的设计、实现和核磁共振(NMR)测量,该植入物在4.7T和11.1T磁场强度下分别将核磁共振图像的信号灵敏度提高3.8dB和2.6dB。该器件通过强耦合共振无线供电方案支持持续可靠的运行,此外还将感兴趣区域内的高分辨率图像信噪比提高到73%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信