Application of independent component analysis for estimating nitrate contamination in natural water sources using planar electromagnetic sensor

M. Yunus, S. Mukhopadhyay, A. Punchihewa
{"title":"Application of independent component analysis for estimating nitrate contamination in natural water sources using planar electromagnetic sensor","authors":"M. Yunus, S. Mukhopadhyay, A. Punchihewa","doi":"10.1109/ICSENST.2011.6137037","DOIUrl":null,"url":null,"abstract":"A system that measures impedance of a planar electromagnetic sensor is described in this paper. It has been used to estimate the amount of nitrate contamination in water samples with the assistance of a method based on independent component analysis. Nitrates sample in the form of ammonium nitrates (NH4NO3), each of different concentration between 5 mg and 20 mg dissolved in 1 litre of deionized water (mili-q) was used as one of the main references. A model based on independent component analysis was developed to estimate nitrate contamination. The model was tested with eight sets of mixed NH4NO3 and (NH4)2HPO4 water samples. From the results, the model can acceptably detect the presence of nitrate added in distilled water and capable of distinguishing the concentration level in the presence of other type of contamination. The system and approach presented in this paper has the potential to be used as a useful tool for water sources monitoring.","PeriodicalId":202062,"journal":{"name":"2011 Fifth International Conference on Sensing Technology","volume":"48 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 Fifth International Conference on Sensing Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENST.2011.6137037","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

Abstract

A system that measures impedance of a planar electromagnetic sensor is described in this paper. It has been used to estimate the amount of nitrate contamination in water samples with the assistance of a method based on independent component analysis. Nitrates sample in the form of ammonium nitrates (NH4NO3), each of different concentration between 5 mg and 20 mg dissolved in 1 litre of deionized water (mili-q) was used as one of the main references. A model based on independent component analysis was developed to estimate nitrate contamination. The model was tested with eight sets of mixed NH4NO3 and (NH4)2HPO4 water samples. From the results, the model can acceptably detect the presence of nitrate added in distilled water and capable of distinguishing the concentration level in the presence of other type of contamination. The system and approach presented in this paper has the potential to be used as a useful tool for water sources monitoring.
独立分量分析在平面电磁传感器估计天然水源硝酸盐污染中的应用
本文介绍了一种测量平面电磁传感器阻抗的系统。在独立成分分析方法的帮助下,它被用于估计水样中硝酸盐污染的量。硝酸盐样品以硝酸铵(NH4NO3)的形式,每种浓度在5mg - 20mg之间溶解于1升去离子水(mili-q)中作为主要参考之一。建立了基于独立成分分析的硝酸盐污染估算模型。采用8组NH4NO3和(NH4)2HPO4混合水样对模型进行了测试。从结果来看,该模型可以较好地检测到蒸馏水中添加的硝酸盐的存在,并且能够在存在其他类型污染的情况下区分浓度水平。本文提出的系统和方法有潜力作为一种有用的水源监测工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信