Transient analysis of Jang-Bin wind farm connected to Taiwan power system

Li Wang, Cheng-Tai Wu, Che-Hao Chang
{"title":"Transient analysis of Jang-Bin wind farm connected to Taiwan power system","authors":"Li Wang, Cheng-Tai Wu, Che-Hao Chang","doi":"10.1109/CACS.2013.6734178","DOIUrl":null,"url":null,"abstract":"This paper presents the transient analyzed results of Jang-Bin wind farm connected to the simplified Taiwan Power System through a transmission line. The q-d axis equivalent-circuit model is developed to establish the complete system model by integrating the 46-MW wind farm and the simplified Taiwan Power System under three-phase balanced loading conditions. It can be concluded from the transient analyzed simulation results that the studied simplified Taiwan Power System connected with Jang-Bin wind farm is stable subject to a severe fault.","PeriodicalId":186492,"journal":{"name":"2013 CACS International Automatic Control Conference (CACS)","volume":"74 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 CACS International Automatic Control Conference (CACS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CACS.2013.6734178","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper presents the transient analyzed results of Jang-Bin wind farm connected to the simplified Taiwan Power System through a transmission line. The q-d axis equivalent-circuit model is developed to establish the complete system model by integrating the 46-MW wind farm and the simplified Taiwan Power System under three-phase balanced loading conditions. It can be concluded from the transient analyzed simulation results that the studied simplified Taiwan Power System connected with Jang-Bin wind farm is stable subject to a severe fault.
长滨风电场与台湾电力系统的暂态分析
本文介绍了通过传输线与简化台湾电力系统连接的长滨风电场的暂态分析结果。建立了q-d轴等效电路模型,将46 mw风电场与简化后的台湾电力系统集成在三相平衡负荷条件下,建立了完整的系统模型。从暂态分析仿真结果可以看出,所研究的简化的与长滨风电场连接的台湾电力系统在发生严重故障时是稳定的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信