[Changes in efficiency of orthodontic tooth movement resulting from differences in bracket materials].

S Matsubara, K Tanne, T Shibaguchi, M Sakuda, J Takahashi, H Kimura
{"title":"[Changes in efficiency of orthodontic tooth movement resulting from differences in bracket materials].","authors":"S Matsubara,&nbsp;K Tanne,&nbsp;T Shibaguchi,&nbsp;M Sakuda,&nbsp;J Takahashi,&nbsp;H Kimura","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The distance of distal movement of the lower canine was measured, using metal tooth with metal bracket and three types of ceramic bracket (polycrystal alumina x 2, zirconia x 1). Sizes of the wires used in this experiment were 0.018\" round, 0.016\" x 0.022\" and 0.17\" x 0.022\". The bracket slot and the wire surface employed in the experiment were observed by use of stereoscopic microscope and S.E.M. The following results were obtained. 1. The distance of tooth movement with three types of ceramic bracket was significantly less than that with the metal bracket. 2. Rate of decrease in tooth movement with three types of ceramic bracket ranged from 30% to 60% in comparison with the metal bracket. 3. The wire surface was obviously scratched by the ceramic brackets, whereas slight scratch was observed on the wire with the metal bracket. 4. The distance of tooth movement decreased associated with an increase of wire size. 5. The distance retracted from the cuspal position was less than that from the cervical point. It was shown that efficiency of tooth movement was significantly reduced by the use of ceramic brackets in comparison with the metal bracket. This result seems to be caused by the frictional resistance between the wire and ceramic bracket. It is suggested that refinement of ceramic brackets, slot edge and surface in particular, would produce more efficient and desirable tooth movements in clinical orthodontics.</p>","PeriodicalId":75367,"journal":{"name":"[Osaka Daigaku shigaku zasshi] The journal of Osaka University Dental Society","volume":"35 1","pages":"355-64"},"PeriodicalIF":0.0000,"publicationDate":"1990-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"[Osaka Daigaku shigaku zasshi] The journal of Osaka University Dental Society","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The distance of distal movement of the lower canine was measured, using metal tooth with metal bracket and three types of ceramic bracket (polycrystal alumina x 2, zirconia x 1). Sizes of the wires used in this experiment were 0.018" round, 0.016" x 0.022" and 0.17" x 0.022". The bracket slot and the wire surface employed in the experiment were observed by use of stereoscopic microscope and S.E.M. The following results were obtained. 1. The distance of tooth movement with three types of ceramic bracket was significantly less than that with the metal bracket. 2. Rate of decrease in tooth movement with three types of ceramic bracket ranged from 30% to 60% in comparison with the metal bracket. 3. The wire surface was obviously scratched by the ceramic brackets, whereas slight scratch was observed on the wire with the metal bracket. 4. The distance of tooth movement decreased associated with an increase of wire size. 5. The distance retracted from the cuspal position was less than that from the cervical point. It was shown that efficiency of tooth movement was significantly reduced by the use of ceramic brackets in comparison with the metal bracket. This result seems to be caused by the frictional resistance between the wire and ceramic bracket. It is suggested that refinement of ceramic brackets, slot edge and surface in particular, would produce more efficient and desirable tooth movements in clinical orthodontics.

【托架材料不同导致正畸牙齿移动效率的变化】。
测量下犬齿的远端运动距离,使用金属牙带金属托架和三种陶瓷托架(多晶氧化铝× 2,氧化锆× 1)。实验中使用的金属丝尺寸分别为0.018"圆,0.016" × 0.022"和0.17" × 0.022"。利用立体显微镜和扫描电镜对实验中使用的支架槽和金属丝表面进行了观察,得到如下结果:1. 三种陶瓷托槽的牙体运动距离均明显小于金属托槽。2. 与金属托架相比,三种类型的陶瓷托架的牙齿运动减少率从30%到60%不等。3.陶瓷支架对导线表面有明显的划伤,而金属支架对导线表面有轻微的划伤。4. 齿的运动距离随钢丝尺寸的增大而减小。5. 离牙尖位置的距离小于离颈点的距离。结果表明,与金属托槽相比,陶瓷托槽的使用显著降低了齿的运动效率。这一结果似乎是由金属丝和陶瓷支架之间的摩擦阻力引起的。建议在临床正畸治疗中,改进陶瓷托槽,特别是槽边和槽面,可以使牙齿运动更有效、更理想。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信