The Harmonic Mitigation in the Smelting Industry Connected to Active Distribution Network in Phetchaburi Province Using Single-Tuned Passive Harmonic Filters Considering Load Demand

Sermsak Kor.srisuwan, Natin Janjamraj, K. Bhumkittipich, S. Romphochai
{"title":"The Harmonic Mitigation in the Smelting Industry Connected to Active Distribution Network in Phetchaburi Province Using Single-Tuned Passive Harmonic Filters Considering Load Demand","authors":"Sermsak Kor.srisuwan, Natin Janjamraj, K. Bhumkittipich, S. Romphochai","doi":"10.1109/ICPEI55293.2022.9986542","DOIUrl":null,"url":null,"abstract":"A large number of nonlinear loads have been implemented in modern power systems, such as electric vehicles, electronic ballasts, and equipment inverter circuits. Moreover, most industrial devices have adopted inverters, including mining, metal smelting, and textile industries. The mentioned nonlinear loads cause harmonics in the power system, resulting in greater power loss, fail protection, and a shorter lifespan. Therefore, this paper presents the harmonic mitigation in the smelting industry connected to the active distribution network in Phetchaburi province using single-tuned passive harmonic filters considering load demand. To determine the suitable single-tuned harmonic filters for reducing harmonics in various load ranges by using the data of the smelting industry, the actual load profile is measured and analyzed as the average value for the proposed method. The simulation results are carried out using DIgSILENT PowerFactory software to verify the proposed method performances, consisting of three scenarios, which are light, normal, and peak loads. The results show that the single-tuned passive harmonic filters using the proposed average load demand-based passive filter method can reduce the harmonic currents of 7th, 9th, and 11th for various load conditions and also improve the harmonic distortion of the power system and the total harmonic distortion of current, satisfying the PEA grid code requirement.","PeriodicalId":223538,"journal":{"name":"2022 International Conference on Power, Energy and Innovations (ICPEI)","volume":"18 6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 International Conference on Power, Energy and Innovations (ICPEI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPEI55293.2022.9986542","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

A large number of nonlinear loads have been implemented in modern power systems, such as electric vehicles, electronic ballasts, and equipment inverter circuits. Moreover, most industrial devices have adopted inverters, including mining, metal smelting, and textile industries. The mentioned nonlinear loads cause harmonics in the power system, resulting in greater power loss, fail protection, and a shorter lifespan. Therefore, this paper presents the harmonic mitigation in the smelting industry connected to the active distribution network in Phetchaburi province using single-tuned passive harmonic filters considering load demand. To determine the suitable single-tuned harmonic filters for reducing harmonics in various load ranges by using the data of the smelting industry, the actual load profile is measured and analyzed as the average value for the proposed method. The simulation results are carried out using DIgSILENT PowerFactory software to verify the proposed method performances, consisting of three scenarios, which are light, normal, and peak loads. The results show that the single-tuned passive harmonic filters using the proposed average load demand-based passive filter method can reduce the harmonic currents of 7th, 9th, and 11th for various load conditions and also improve the harmonic distortion of the power system and the total harmonic distortion of current, satisfying the PEA grid code requirement.
考虑负荷需求的单调谐无源谐波滤波器对Phetchaburi省有源配电网冶炼工业的谐波抑制
在现代电力系统中,如电动汽车、电子镇流器和设备逆变电路中都存在大量的非线性负载。此外,大多数工业设备都采用了逆变器,包括采矿,金属冶炼和纺织工业。上述非线性负载在电力系统中引起谐波,导致更大的功率损耗、故障保护和更短的寿命。因此,本文提出了在考虑负荷需求的情况下,采用单调谐无源谐波滤波器对与Phetchaburi省有源配电网连接的冶炼行业进行谐波缓解。为了利用冶炼行业的数据,确定适合在不同负荷范围内降低谐波的单调谐滤波器,对实际负荷剖面进行了测量和分析,作为所提出方法的平均值。利用DIgSILENT PowerFactory软件进行仿真,验证了该方法在轻负荷、正常负荷和峰值负荷三种情况下的性能。结果表明,采用基于平均负荷需求的无源滤波方法设计的单调谐无源谐波滤波器,在各种负荷条件下均能降低7、9、11路谐波电流,改善电力系统谐波畸变和电流总谐波畸变,满足PEA电网规范要求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书