[Sensory responses to Nd:YAG laser irradiation in humans].

Aichi Gakuin Daigaku Shigakkai shi Pub Date : 1990-06-01
A Ito, K Kakami, K Yoshida, M Fukaya
{"title":"[Sensory responses to Nd:YAG laser irradiation in humans].","authors":"A Ito,&nbsp;K Kakami,&nbsp;K Yoshida,&nbsp;M Fukaya","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Pain and detection thresholds upon Nd:YAG laser irradiation were studied in healthy human subjects. The output power was set at 100 mW (1.36 W/cm2), 300 mW (4.11 W/cm2), 600 mW (8.22 W/cm2), 800 mW (11.0 W/cm2) and 1,000 mW (13.7 W/cm2). The duration was 5 seconds. The irradiation was done to the hand dorsum using the non-contact method (distance between the subject and the laser tip was 5.0 mm). After irradiation, the detection threshold was about 600 mW and the pain threshold was about 1,000 mW. The skin temperature was 34.9 +/- 0.64 degrees C before irradiation and 38.0 +/- 0.45 degrees C after a 5-sec-irradiation at 1,000 mW. No skin damage was observed after the irradiations.</p>","PeriodicalId":75458,"journal":{"name":"Aichi Gakuin Daigaku Shigakkai shi","volume":"28 2","pages":"613-7"},"PeriodicalIF":0.0000,"publicationDate":"1990-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Aichi Gakuin Daigaku Shigakkai shi","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Pain and detection thresholds upon Nd:YAG laser irradiation were studied in healthy human subjects. The output power was set at 100 mW (1.36 W/cm2), 300 mW (4.11 W/cm2), 600 mW (8.22 W/cm2), 800 mW (11.0 W/cm2) and 1,000 mW (13.7 W/cm2). The duration was 5 seconds. The irradiation was done to the hand dorsum using the non-contact method (distance between the subject and the laser tip was 5.0 mm). After irradiation, the detection threshold was about 600 mW and the pain threshold was about 1,000 mW. The skin temperature was 34.9 +/- 0.64 degrees C before irradiation and 38.0 +/- 0.45 degrees C after a 5-sec-irradiation at 1,000 mW. No skin damage was observed after the irradiations.

[人体对Nd:YAG激光照射的感觉反应]。
研究了Nd:YAG激光照射人体的疼痛和检测阈值。输出功率分别为100 mW (1.36 W/cm2)、300 mW (4.11 W/cm2)、600 mW (8.22 W/cm2)、800 mW (11.0 W/cm2)和1000 mW (13.7 W/cm2)。持续时间为5秒。采用非接触法对手背进行照射(受试者与激光尖端的距离为5.0 mm)。辐照后,检测阈值约为600mw,疼痛阈值约为1000mw。辐照前皮肤温度为34.9 +/- 0.64℃,辐照5秒后皮肤温度为38.0 +/- 0.45℃。照射后未见皮肤损伤。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信