[Basic investigation using K6 diagnostic system. 3. Fabrication of the apparatus wearing a Sensor Alley and the evaluation of its accuracy].

Aichi Gakuin Daigaku Shigakkai shi Pub Date : 1990-09-01
E Aida, S Imamura, K Kurosu
{"title":"[Basic investigation using K6 diagnostic system. 3. Fabrication of the apparatus wearing a Sensor Alley and the evaluation of its accuracy].","authors":"E Aida,&nbsp;S Imamura,&nbsp;K Kurosu","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Unlabelled: </strong>An investigation was undertaken to evaluated the accuracy of Sensor Alley, a mandibular movement analyser: K6 Diagnostic System EX with a newly designed auxiliary apparatus.</p><p><strong>Results: </strong>1) The errors in the values of the standard Sensor Alley were 4.8 mm for the VER-coordinate, 5.0 mm for the AP-coordinate and 3.0 mm for LA-coordinate. 2) The errors of the AP-coordinate were bigger than those of the VER and LA-coordinates. 3) The errors in the values of the standard Sensor Alley fitted with a newly designed auxiliary apparatus were 0.9 mm for the VER-coordinate, 2.0 mm for the AP-coordinate and 1.1 mm for the LA-coordinate. 4) The results led to the conclusion that this newly designed auxiliary apparatus was useful for various studies on mandibular movement used with the K6 Diagnostic System EX.</p>","PeriodicalId":75458,"journal":{"name":"Aichi Gakuin Daigaku Shigakkai shi","volume":"28 3","pages":"797-802"},"PeriodicalIF":0.0000,"publicationDate":"1990-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Aichi Gakuin Daigaku Shigakkai shi","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Unlabelled: An investigation was undertaken to evaluated the accuracy of Sensor Alley, a mandibular movement analyser: K6 Diagnostic System EX with a newly designed auxiliary apparatus.

Results: 1) The errors in the values of the standard Sensor Alley were 4.8 mm for the VER-coordinate, 5.0 mm for the AP-coordinate and 3.0 mm for LA-coordinate. 2) The errors of the AP-coordinate were bigger than those of the VER and LA-coordinates. 3) The errors in the values of the standard Sensor Alley fitted with a newly designed auxiliary apparatus were 0.9 mm for the VER-coordinate, 2.0 mm for the AP-coordinate and 1.1 mm for the LA-coordinate. 4) The results led to the conclusion that this newly designed auxiliary apparatus was useful for various studies on mandibular movement used with the K6 Diagnostic System EX.

K6诊断系统的基础调查。3.带传感器通道装置的制作及其精度评价[j]。
未标记:进行了一项调查,以评估Sensor Alley的准确性,这是一种下颌运动分析仪:K6诊断系统EX与新设计的辅助设备。结果:1)标准Sensor Alley值在ver坐标下误差4.8 mm, ap坐标下误差5.0 mm, la坐标下误差3.0 mm。2) ap -坐标误差大于VER和la -坐标误差。3)安装新设计的辅助装置后,标准Sensor Alley的值误差为ver坐标0.9 mm, ap坐标2.0 mm, la坐标1.1 mm。4)结果表明,这种新设计的辅助器械可用于与K6诊断系统EX配合使用的各种下颌运动研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信