Current‐limiting Universal Droop Controller

Qing-Chang Zhong
{"title":"Current‐limiting Universal Droop Controller","authors":"Qing-Chang Zhong","doi":"10.1002/9781118803516.ch20","DOIUrl":null,"url":null,"abstract":"Power electronic converters are known to be vulnerable to excessive over‐currents. This chapter presents a current‐limiting universal droop controller to operate a grid‐connected inverter under both normal and faulty grid conditions. The system consists of a single‐phase inverter connected to the grid via an LCL filter. The chapter focuses on the design of the virtual resistance to obtain the desired current‐limiting property. In contrast to existing current‐limiting approaches, the current limitation is achieved without external limiters, additional switches or monitoring devices. Furthermore, this function is independent of grid voltage and frequency variations, achieving desired control performance under grid faults as well. The chapter also presents extensive experimental results to verify the droop function of the controller and its current‐limiting capability under normal and faulty grid conditions.","PeriodicalId":312799,"journal":{"name":"Power Electronics‐Enabled Autonomous Power Systems","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Power Electronics‐Enabled Autonomous Power Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/9781118803516.ch20","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Power electronic converters are known to be vulnerable to excessive over‐currents. This chapter presents a current‐limiting universal droop controller to operate a grid‐connected inverter under both normal and faulty grid conditions. The system consists of a single‐phase inverter connected to the grid via an LCL filter. The chapter focuses on the design of the virtual resistance to obtain the desired current‐limiting property. In contrast to existing current‐limiting approaches, the current limitation is achieved without external limiters, additional switches or monitoring devices. Furthermore, this function is independent of grid voltage and frequency variations, achieving desired control performance under grid faults as well. The chapter also presents extensive experimental results to verify the droop function of the controller and its current‐limiting capability under normal and faulty grid conditions.
限流通用下垂控制器
众所周知,电力电子转换器容易受到过大过电流的影响。本章介绍了一种限流通用下垂控制器,用于在正常和故障电网条件下操作并网逆变器。该系统由一个单相逆变器组成,通过LCL滤波器连接到电网。本章的重点是虚拟电阻的设计,以获得所需的限流性能。与现有的电流限制方法相比,电流限制是在没有外部限制器、额外开关或监控设备的情况下实现的。此外,该函数不受电网电压和频率变化的影响,在电网故障情况下也能达到理想的控制性能。本章还介绍了大量的实验结果,以验证控制器的下垂函数及其在正常和故障电网条件下的限流能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信