Experimental Study of Film Cooling With Favorable and Adverse Pressure Gradients

R. Volino, Matthew C. Gillcrist
{"title":"Experimental Study of Film Cooling With Favorable and Adverse Pressure Gradients","authors":"R. Volino, Matthew C. Gillcrist","doi":"10.1115/gt2022-78240","DOIUrl":null,"url":null,"abstract":"\n Film cooling experiments were conducted on a flat wall subject to favorable and adverse pressure gradients with constant acceleration parameter, K. The test wall included a single row of 5 round holes in line with the flow direction and inclined at 35 degrees to the surface. The hole spacing was 3 diameters. The wall opposite the test wall was moveable, and was set to angles with respect to the test wall that produced K values of −0.5 × 10−6, 0, 1 × 10−6, 2 × 10−6, 2.5 × 10−6, and 3 × 10−6. Blowing ratios of 0, 0.5, 1, and 1.5 were tested at each acceleration. The test wall was equipped with constant flux surface heaters, and data were acquired for each flow condition with the wall both heated and unheated. An infrared camera was used to record wall temperature in a region spanning the three center holes and extending 20D downstream of the holes. From these measurements, local film cooling effectiveness and heat transfer coefficients were determined. In the flow, velocity and temperature profiles were acquired using hot-wire anemometry and a traversing thermocouple probe. Particle image velocimetry was used to acquire velocity fields in a plane perpendicular to the flow direction and 10D downstream of the holes. The pressure gradient had a noticeable effect on the flow, with the favorable pressure gradient reducing liftoff and moving the film cooling jets closer to the wall, and reducing turbulence levels in the boundary layer. The adverse pressure gradient had the opposite effect. Near the wall, however, the effects of the pressure gradient on the film cooling effectiveness and heat transfer were more subtle.","PeriodicalId":267158,"journal":{"name":"Volume 6A: Heat Transfer — Combustors; Film Cooling","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 6A: Heat Transfer — Combustors; Film Cooling","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/gt2022-78240","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Film cooling experiments were conducted on a flat wall subject to favorable and adverse pressure gradients with constant acceleration parameter, K. The test wall included a single row of 5 round holes in line with the flow direction and inclined at 35 degrees to the surface. The hole spacing was 3 diameters. The wall opposite the test wall was moveable, and was set to angles with respect to the test wall that produced K values of −0.5 × 10−6, 0, 1 × 10−6, 2 × 10−6, 2.5 × 10−6, and 3 × 10−6. Blowing ratios of 0, 0.5, 1, and 1.5 were tested at each acceleration. The test wall was equipped with constant flux surface heaters, and data were acquired for each flow condition with the wall both heated and unheated. An infrared camera was used to record wall temperature in a region spanning the three center holes and extending 20D downstream of the holes. From these measurements, local film cooling effectiveness and heat transfer coefficients were determined. In the flow, velocity and temperature profiles were acquired using hot-wire anemometry and a traversing thermocouple probe. Particle image velocimetry was used to acquire velocity fields in a plane perpendicular to the flow direction and 10D downstream of the holes. The pressure gradient had a noticeable effect on the flow, with the favorable pressure gradient reducing liftoff and moving the film cooling jets closer to the wall, and reducing turbulence levels in the boundary layer. The adverse pressure gradient had the opposite effect. Near the wall, however, the effects of the pressure gradient on the film cooling effectiveness and heat transfer were more subtle.
有利压力梯度和不利压力梯度下气膜冷却的实验研究
在恒定加速度参数k下,在正逆压梯度作用下的平面壁面上进行气膜冷却实验。实验壁面为一排5个圆孔,沿流动方向排列,与表面呈35度倾斜。井眼间距为3个直径。与试验壁相对的壁是可移动的,并与试验壁设置成一定角度,产生的K值为- 0.5 × 10−6、0,1 × 10−6、2 × 10−6、2.5 × 10−6和3 × 10−6。在每个加速度下分别测试吹气比0、0.5、1和1.5。试验壁面安装了恒流量表面加热器,并采集了壁面加热和未加热两种流动状态下的数据。利用红外摄像机记录了横跨三个中心孔并向孔下游延伸20D的区域壁面温度。从这些测量中,确定了局部膜冷却效率和传热系数。在流动中,速度和温度分布是通过热线风速法和一个穿越热电偶探头获得的。采用粒子图像测速技术获取垂直于流动方向平面和孔下游10D平面上的速度场。压力梯度对流动有明显的影响,有利的压力梯度降低了升力,使膜冷却射流更靠近壁面,降低了边界层的湍流水平。逆压梯度则有相反的效果。而在壁面附近,压力梯度对膜冷效果和传热的影响更为细微。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信