Design of an Oxistimulator system for use in clinical trials

J. Kuhlmann, Steven Deick
{"title":"Design of an Oxistimulator system for use in clinical trials","authors":"J. Kuhlmann, Steven Deick","doi":"10.1109/MeMeA.2017.7985871","DOIUrl":null,"url":null,"abstract":"Obstructive sleep apnea, especially when undiagnosed, can be a critical issue for surgical patients in the days following surgery due to lingering effects of anesthesia that may depress their auto-response to recover from episodes of apnea. The authors worked in collaboration with medical staff to develop a custom system in support of a clinical research study. The Oxistimulator system provides a low-level electrical stimulation to a patient in response to oxygen saturation levels dropping below a defined threshold for patient safety, and tracks data required to analyze the system's effectiveness. A successful outcome of the study could help justify a new medical device that would improve patient safety during post-anesthesia recovery.","PeriodicalId":235051,"journal":{"name":"2017 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","volume":"91 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MeMeA.2017.7985871","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Obstructive sleep apnea, especially when undiagnosed, can be a critical issue for surgical patients in the days following surgery due to lingering effects of anesthesia that may depress their auto-response to recover from episodes of apnea. The authors worked in collaboration with medical staff to develop a custom system in support of a clinical research study. The Oxistimulator system provides a low-level electrical stimulation to a patient in response to oxygen saturation levels dropping below a defined threshold for patient safety, and tracks data required to analyze the system's effectiveness. A successful outcome of the study could help justify a new medical device that would improve patient safety during post-anesthesia recovery.
用于临床试验的氧刺激系统的设计
阻塞性睡眠呼吸暂停,特别是在未确诊的情况下,可能是手术后几天手术患者的一个关键问题,因为麻醉的持续影响可能会抑制他们从呼吸暂停发作中恢复的自身反应。作者与医务人员合作开发了一个支持临床研究的定制系统。当血氧饱和度低于患者安全规定的阈值时,oxisstimulator系统可向患者提供低水平电刺激,并跟踪分析系统有效性所需的数据。这项研究的成功结果可能有助于证明一种新的医疗设备可以提高患者在麻醉后恢复期间的安全性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信