{"title":"Research on dynamic characteristics of inverter when fault occurs in HVDC receiving end equipped with synchronous condenser","authors":"L. Luo, Tao Pang","doi":"10.1109/APPEEC50844.2021.9687711","DOIUrl":null,"url":null,"abstract":"High voltage direct current (HVDC) is more and more widely used in the world. Its grid connection brings stability problems to the traditional AC power grid. As a common fault of HVDC, commutation failure usually occurs at the receiving end. In this paper, the typical circuit structure and control strategy of HVDC are used to analyze the dynamic characteristics of inverter to AC side fault of receiving end under different transmission power, and the influence of Synchronous condenser (SC) and filter compensation device (FC) on AC side fault of receiving end is analyzed. Finally, based on the parameters of Jiuquan Hunan HVDC transmission project, the correctness of the analysis is verified by simulation on PSCAD / EMTDC.","PeriodicalId":345537,"journal":{"name":"2021 13th IEEE PES Asia Pacific Power & Energy Engineering Conference (APPEEC)","volume":"241 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 13th IEEE PES Asia Pacific Power & Energy Engineering Conference (APPEEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APPEEC50844.2021.9687711","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

High voltage direct current (HVDC) is more and more widely used in the world. Its grid connection brings stability problems to the traditional AC power grid. As a common fault of HVDC, commutation failure usually occurs at the receiving end. In this paper, the typical circuit structure and control strategy of HVDC are used to analyze the dynamic characteristics of inverter to AC side fault of receiving end under different transmission power, and the influence of Synchronous condenser (SC) and filter compensation device (FC) on AC side fault of receiving end is analyzed. Finally, based on the parameters of Jiuquan Hunan HVDC transmission project, the correctness of the analysis is verified by simulation on PSCAD / EMTDC.
安装同步冷凝器的高压直流接收端发生故障时逆变器的动态特性研究
高压直流(HVDC)在世界范围内得到越来越广泛的应用。它的并网给传统的交流电网带来了稳定性问题。换相故障是高压直流的常见故障,通常发生在接收端。本文采用高压直流输电的典型电路结构和控制策略,分析了不同传输功率下逆变器对接收端交流侧故障的动态特性,分析了同步电容器(SC)和滤波补偿装置(FC)对接收端交流侧故障的影响。最后,以湖南酒泉直流输电工程为例,通过PSCAD / EMTDC仿真验证了分析的正确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信