Impact of Proton Irradiation on SiPM Dark Current for High-Energy Space Instruments

K. Lacombe, I. Belkacem, B. Houret, J. Knödlseder, P. Ramon, A. Bardoux, T. Gimenez
{"title":"Impact of Proton Irradiation on SiPM Dark Current for High-Energy Space Instruments","authors":"K. Lacombe, I. Belkacem, B. Houret, J. Knödlseder, P. Ramon, A. Bardoux, T. Gimenez","doi":"10.7566/jpscp.27.012006","DOIUrl":null,"url":null,"abstract":"As photon detection is a major issue in any high-energy astronomy instrumentation, many space missions combined photomultiplier tubes (PMTs) with scintillators, for converting incoming high-energy photons into visible light, which in turn is converted in an electrical pulse. The silicon photomultipliers (SiPM), instead of PMTs which are bulky, fragile, and requiring a high-voltage power supply of up to several thousand volts, seem to be an encouraging alternative in the space field. We started a R&D program to assess the possibility of using SiPMs for space-based applications in the domain of high-energy astronomy. We already presented some results of the detector characterization to study the SiPM performance in a representative space environment, namely at low temperature and low pressure. For this purpose, we developed a dedicated vacuum chamber with a specific mechanical and thermal controlled system. After measuring dark current, dark count rate and PDE (Photon Detection Efficiency), we performed a first campaign of irradiation tests at UCL (Belgium) in order to understand the susceptibility of SiPM to radiation damage on two selected detectors (Ketek and SensL references) with a high level of fluence. Finally we led a new proton irradiation campaign based on several lower levels of fluence and two energies for further study. We then present the results of dark current measurements of irradiated SensL detectors.","PeriodicalId":228570,"journal":{"name":"Proceedings of the 5th International Workshop on New Photon-Detectors (PD18)","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 5th International Workshop on New Photon-Detectors (PD18)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7566/jpscp.27.012006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

As photon detection is a major issue in any high-energy astronomy instrumentation, many space missions combined photomultiplier tubes (PMTs) with scintillators, for converting incoming high-energy photons into visible light, which in turn is converted in an electrical pulse. The silicon photomultipliers (SiPM), instead of PMTs which are bulky, fragile, and requiring a high-voltage power supply of up to several thousand volts, seem to be an encouraging alternative in the space field. We started a R&D program to assess the possibility of using SiPMs for space-based applications in the domain of high-energy astronomy. We already presented some results of the detector characterization to study the SiPM performance in a representative space environment, namely at low temperature and low pressure. For this purpose, we developed a dedicated vacuum chamber with a specific mechanical and thermal controlled system. After measuring dark current, dark count rate and PDE (Photon Detection Efficiency), we performed a first campaign of irradiation tests at UCL (Belgium) in order to understand the susceptibility of SiPM to radiation damage on two selected detectors (Ketek and SensL references) with a high level of fluence. Finally we led a new proton irradiation campaign based on several lower levels of fluence and two energies for further study. We then present the results of dark current measurements of irradiated SensL detectors.
质子辐照对高能空间仪器SiPM暗电流的影响
由于光子探测是任何高能天文仪器的主要问题,许多太空任务都将光电倍增管(pmt)与闪烁体结合起来,将入射的高能光子转换为可见光,然后将其转换为电脉冲。硅光电倍增管(SiPM)取代了体积庞大、易碎且需要高达几千伏的高压电源的pmt,似乎是太空领域令人鼓舞的替代方案。我们启动了一个研发项目,以评估在高能天文学领域将sipm用于天基应用的可能性。我们已经给出了探测器表征的一些结果,以研究SiPM在具有代表性的空间环境下,即低温和低压下的性能。为此,我们开发了一个专用的真空室,配有特定的机械和热控制系统。在测量了暗电流、暗计数率和PDE(光子探测效率)之后,我们在伦敦大学学院(比利时)进行了第一次辐射测试,以了解SiPM对两个高通量检测器(Ketek和SensL参考文献)的辐射损伤的敏感性。最后,我们领导了一个新的质子辐照运动,该运动基于几个较低的通量和两个能量,以供进一步研究。然后,我们提出了暗电流测量的结果辐照传感器探测器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信