A novel grid interface for photovoltaic, wind-electric, and fuel-cell systems with a controllable power factor of operation

R. Naik, N. Mohan
{"title":"A novel grid interface for photovoltaic, wind-electric, and fuel-cell systems with a controllable power factor of operation","authors":"R. Naik, N. Mohan","doi":"10.1109/APEC.1995.469062","DOIUrl":null,"url":null,"abstract":"This paper presents a novel control for a grid interface, for interconnection of renewable energy sources with a three-phase utility, with a controllable power factor of operation. The total harmonic distortion in the line currents meets the 5% limit recommended by the IEEE 519-1992. The novel control strategy for operating the interface at unity or even slightly leading power factor is described and the simulation results are presented. The grid interface described is based on a novel topology for transferring power from the DC side to the three-phase AC system. It consists of a thyristor inverter where the firing angle can be kept at a constant value. The power flow from the DC source to the utility is controlled by two stepdown DC-DC converters.<<ETX>>","PeriodicalId":335367,"journal":{"name":"Proceedings of 1995 IEEE Applied Power Electronics Conference and Exposition - APEC'95","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 1995 IEEE Applied Power Electronics Conference and Exposition - APEC'95","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC.1995.469062","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

Abstract

This paper presents a novel control for a grid interface, for interconnection of renewable energy sources with a three-phase utility, with a controllable power factor of operation. The total harmonic distortion in the line currents meets the 5% limit recommended by the IEEE 519-1992. The novel control strategy for operating the interface at unity or even slightly leading power factor is described and the simulation results are presented. The grid interface described is based on a novel topology for transferring power from the DC side to the three-phase AC system. It consists of a thyristor inverter where the firing angle can be kept at a constant value. The power flow from the DC source to the utility is controlled by two stepdown DC-DC converters.<>
一种新型的电网接口,用于光伏、风能和燃料电池系统,具有可控的运行功率因数
本文提出了一种新的电网接口控制方法,用于可再生能源与三相公用事业并网,具有可控的运行功率因数。线路电流中的总谐波失真符合IEEE 519-1992推荐的5%限值。介绍了在功率因数相等或略超前情况下操作界面的新型控制策略,并给出了仿真结果。所描述的电网接口基于一种新颖的拓扑结构,用于将电力从直流侧传输到三相交流系统。它由一个可控硅逆变器组成,其中发射角可以保持在恒定值。从直流电源到公用事业的功率流由两个降压DC-DC转换器控制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.20
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信