Optimal location and sizing of STATCOM for voltage security enhancement using PSO-TVAC

S. Varshney, L. Srivastava, M. Pandit
{"title":"Optimal location and sizing of STATCOM for voltage security enhancement using PSO-TVAC","authors":"S. Varshney, L. Srivastava, M. Pandit","doi":"10.1109/ICPES.2011.6156646","DOIUrl":null,"url":null,"abstract":"STATCOM is a second generation, shunt connected Flexible AC Transmission Systems (FACTS) device. STATCOM is used to support bus voltage by injecting or absorbing the reactive power, therefore it is capable to enhance voltage security. However, owing to the considerable cost of the FACTS device involved, it is important to find the optimal location and sizing of the device in a power system to obtain maximum benefits of the devices. In this paper, most severe single line outage contingencies are considered for finding optimal location and sizing of STATCOM in a power system. As a first step, contingency ranking is performed to determine the most severe line outages by evaluating voltage performance index (VPI). Thereafter Particle Swarm Optimization-Time Varying Acceleration Coefficients (PSO-TVAC) algorithm is used to find the location and size of STATCOM. The proposed methodology is demonstrated on standard IEEE 30-bus system.","PeriodicalId":158903,"journal":{"name":"2011 International Conference on Power and Energy Systems","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Power and Energy Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPES.2011.6156646","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

Abstract

STATCOM is a second generation, shunt connected Flexible AC Transmission Systems (FACTS) device. STATCOM is used to support bus voltage by injecting or absorbing the reactive power, therefore it is capable to enhance voltage security. However, owing to the considerable cost of the FACTS device involved, it is important to find the optimal location and sizing of the device in a power system to obtain maximum benefits of the devices. In this paper, most severe single line outage contingencies are considered for finding optimal location and sizing of STATCOM in a power system. As a first step, contingency ranking is performed to determine the most severe line outages by evaluating voltage performance index (VPI). Thereafter Particle Swarm Optimization-Time Varying Acceleration Coefficients (PSO-TVAC) algorithm is used to find the location and size of STATCOM. The proposed methodology is demonstrated on standard IEEE 30-bus system.
利用PSO-TVAC增强电压安全性的STATCOM的最佳位置和尺寸
STATCOM是第二代,并联的柔性交流传输系统(FACTS)设备。STATCOM通过注入或吸收无功功率来支持母线电压,因此能够增强电压安全性。然而,由于所涉及的FACTS器件的成本相当大,因此找到器件在电力系统中的最佳位置和尺寸以获得器件的最大效益非常重要。本文考虑了电力系统中最严重的单线停电事故,以确定STATCOM的最优位置和规模。首先,通过评估电压性能指数(VPI)进行应急排序,确定最严重的线路中断。在此基础上,采用粒子群优化-时变加速度系数(PSO-TVAC)算法确定了STATCOM的位置和大小。该方法在标准的IEEE 30总线系统上进行了验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信