Anechoic chamber related issues for very large automated planar near field range

S. Christopher, A. Rao, S. Varughese, M. Easwaran
{"title":"Anechoic chamber related issues for very large automated planar near field range","authors":"S. Christopher, A. Rao, S. Varughese, M. Easwaran","doi":"10.1109/ICEMIC.1997.669770","DOIUrl":null,"url":null,"abstract":"LRDE has set up an automated planar near field measurement facility with a size of 18 m/spl times/12 m/spl times/10 m. This paper discusses anechoic chamber related issues, such as the requirement of the absorbers, quiet zone etc. which were faced during the design stage. A novel technique to enhance the quiet zone with commercially available absorbers, with -40 to -50 dB reflectivity is explained.","PeriodicalId":444507,"journal":{"name":"Proceedings of the International Conference on Electromagnetic Interference and Compatibility '99 (IEEE Cat. No. 99TH 8487)","volume":"50 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-12-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the International Conference on Electromagnetic Interference and Compatibility '99 (IEEE Cat. No. 99TH 8487)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEMIC.1997.669770","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

LRDE has set up an automated planar near field measurement facility with a size of 18 m/spl times/12 m/spl times/10 m. This paper discusses anechoic chamber related issues, such as the requirement of the absorbers, quiet zone etc. which were faced during the design stage. A novel technique to enhance the quiet zone with commercially available absorbers, with -40 to -50 dB reflectivity is explained.
消声室的相关问题,适用于非常大的自动化平面近场范围
LRDE已经建立了一个自动化的平面近场测量设备,尺寸为18米/12米/10米。本文讨论了消声室在设计阶段所面临的消声室相关问题,如消声室对吸声器的要求、消声区等。介绍了一种利用商用吸收器增强安静区的新技术,其反射率为-40至-50 dB。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信