[Sensitization to ethylene oxide: a possible cause of reactions in hemodialysis patients].

C Tosoni, A Apollonio, N Carabellese, R Cattaneo, F Soldati, M Campanini, A Castiglione, P Scalia, M Romagnani, G Sorgato
{"title":"[Sensitization to ethylene oxide: a possible cause of reactions in hemodialysis patients].","authors":"C Tosoni,&nbsp;A Apollonio,&nbsp;N Carabellese,&nbsp;R Cattaneo,&nbsp;F Soldati,&nbsp;M Campanini,&nbsp;A Castiglione,&nbsp;P Scalia,&nbsp;M Romagnani,&nbsp;G Sorgato","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>147 hemodialyzed patient were studied for the presence of allergic reactions related to the dialytic treatment. Total IgE and specific IgE to common inhalants, ethylene oxide and phthalic anhydride were determined in all patients. The same determinations were also performed in two control groups. Specific IgE to ethylene oxide were detected in 7 sera. Among these 6 had a high total IgE level and 2 had a positive Phadiatop. Only 3 among the 7 positive patients had adverse reactions related to the hemodialysis (one suffered from itching, one from urticaria and the third from angioedema and hypotension). The resolution of the symptoms was obtained utilizing a gamma-rays sterilized filter. Therefore ethylene oxide sensitization may be a cause of some problems during hemodialysis. We couldn't find a relationship between atopic status and sensitization to ethylene oxide in as much in only 2 out of 7 patients sensitized to ethylene oxide, specific IgE to common inhalants were detected.</p>","PeriodicalId":75613,"journal":{"name":"Bollettino dell'Istituto sieroterapico milanese","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1990-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bollettino dell'Istituto sieroterapico milanese","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

147 hemodialyzed patient were studied for the presence of allergic reactions related to the dialytic treatment. Total IgE and specific IgE to common inhalants, ethylene oxide and phthalic anhydride were determined in all patients. The same determinations were also performed in two control groups. Specific IgE to ethylene oxide were detected in 7 sera. Among these 6 had a high total IgE level and 2 had a positive Phadiatop. Only 3 among the 7 positive patients had adverse reactions related to the hemodialysis (one suffered from itching, one from urticaria and the third from angioedema and hypotension). The resolution of the symptoms was obtained utilizing a gamma-rays sterilized filter. Therefore ethylene oxide sensitization may be a cause of some problems during hemodialysis. We couldn't find a relationship between atopic status and sensitization to ethylene oxide in as much in only 2 out of 7 patients sensitized to ethylene oxide, specific IgE to common inhalants were detected.

[对环氧乙烷过敏:血液透析患者反应的可能原因]。
对147例血液透析患者进行透析治疗相关过敏反应的研究。测定所有患者对常用吸入剂、环氧乙烷和邻苯二酸酐的总IgE和特异性IgE。在两个对照组中也进行了相同的测定。7份血清检测到环氧乙烷特异性IgE。其中总IgE高6例,Phadiatop阳性2例。7例阳性患者中仅有3例出现与血液透析相关的不良反应(1例出现瘙痒,1例出现荨麻疹,3例出现血管性水肿和低血压)。症状的解决是利用伽马射线消毒过滤器获得的。因此环氧乙烷致敏可能是血液透析过程中一些问题的原因。我们没有发现异位状态与环氧乙烷致敏之间的关系,因为在7例环氧乙烷致敏患者中,只有2例检测到对常见吸入剂的特异性IgE。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信