{"title":"Simulation analysis of modified DC bus voltage control algorithm for power quality improvement on distributed generation systems","authors":"M. Aiswarya, Ilango Karuppasamy, P. Manitha, M. Nair","doi":"10.1109/PESTSE.2014.6805297","DOIUrl":null,"url":null,"abstract":"This paper presents a control strategy for shunt active filter interface for distributed generation scheme without degrading the power quality in the grid. The control strategy used enhances the performance of shunt active filter by sharing active power being generated from distributed generation to grid as well as load in addition to regular functions such as current harmonic elimination, reactive power compensation, power factor correction. The modified control algorithm is designed and analyzed for non-linear load using MATLAB/Simulink. The simulation results shows good performance of controller for power quality improvement of distributed generation system interfaced through shunt active filter.","PeriodicalId":352711,"journal":{"name":"2014 POWER AND ENERGY SYSTEMS: TOWARDS SUSTAINABLE ENERGY","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 POWER AND ENERGY SYSTEMS: TOWARDS SUSTAINABLE ENERGY","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESTSE.2014.6805297","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

This paper presents a control strategy for shunt active filter interface for distributed generation scheme without degrading the power quality in the grid. The control strategy used enhances the performance of shunt active filter by sharing active power being generated from distributed generation to grid as well as load in addition to regular functions such as current harmonic elimination, reactive power compensation, power factor correction. The modified control algorithm is designed and analyzed for non-linear load using MATLAB/Simulink. The simulation results shows good performance of controller for power quality improvement of distributed generation system interfaced through shunt active filter.
改进的分布式发电系统直流母线电压控制算法的仿真分析
针对分布式发电方案,提出了一种不影响电网电能质量的并联有源滤波器接口控制策略。所采用的控制策略除了具有电流谐波消除、无功补偿、功率因数校正等常规功能外,还通过将分布式发电产生的有功功率共享给电网和负荷来提高并联有源滤波器的性能。利用MATLAB/Simulink对非线性负载的改进控制算法进行了设计和分析。仿真结果表明,该控制器通过并联有源滤波器接口改善分布式发电系统的电能质量,具有良好的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信