{"title":"Digital Imaging Based Measurement of Combustion Flame Characteristics","authors":"G. Lu, A. Stasiak, J. Shao, Yong Yan","doi":"10.1109/IST.2007.379607","DOIUrl":null,"url":null,"abstract":"This paper presents the system software development and the experimental calibration of a flame imaging system. The new system software is developed based on a unique architecture through a careful combination of Visual Basic and Visual C programming strategies for better system stability and response time. The imaging system is calibrated using high standard blackbody sources as temperature/light references over the temperature range from 800degC to 1650degC for an improved measurement accuracy of flame temperature. The new system software and calibration curves are evaluated through off-line analysis where flame images captured in previous tests on industry-scale coal combustion test facilities are used. Test results and their comparisons with online data are presented and discussed.","PeriodicalId":329519,"journal":{"name":"2007 IEEE International Workshop on Imaging Systems and Techniques","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-05-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE International Workshop on Imaging Systems and Techniques","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IST.2007.379607","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
This paper presents the system software development and the experimental calibration of a flame imaging system. The new system software is developed based on a unique architecture through a careful combination of Visual Basic and Visual C programming strategies for better system stability and response time. The imaging system is calibrated using high standard blackbody sources as temperature/light references over the temperature range from 800degC to 1650degC for an improved measurement accuracy of flame temperature. The new system software and calibration curves are evaluated through off-line analysis where flame images captured in previous tests on industry-scale coal combustion test facilities are used. Test results and their comparisons with online data are presented and discussed.