Robust voltage-mode control of DC-DC switching converters based on a two-controller scheme

E. Figueres, G. Garcerá, M. Pascual, D. Cerver
{"title":"Robust voltage-mode control of DC-DC switching converters based on a two-controller scheme","authors":"E. Figueres, G. Garcerá, M. Pascual, D. Cerver","doi":"10.1109/ISIE.2002.1025883","DOIUrl":null,"url":null,"abstract":"The purpose of this paper is to present an analog and robust voltage-mode control loop of buck derived converters, which maintains the crossover frequency and the phase margin of the loop gain much closer to the design goals than the conventional loop, even with large variations of the power stage elements. Furthermore, the proposed scheme can achieve that the power stage seen by the voltage regulator becomes a first order system like current-mode controls do. A 5 V-5 A, 50 kHz buck prototype operating from an input voltage ranging from 15 V to 25 V has been experimentally tested with different LC output filters and load conditions, including discontinuous conduction mode. Small-signal and large signal measurements on the prototype have been carried out, showing the robustness properties achieved by the proposed loop.","PeriodicalId":330283,"journal":{"name":"Industrial Electronics, 2002. ISIE 2002. Proceedings of the 2002 IEEE International Symposium on","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Industrial Electronics, 2002. ISIE 2002. Proceedings of the 2002 IEEE International Symposium on","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISIE.2002.1025883","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The purpose of this paper is to present an analog and robust voltage-mode control loop of buck derived converters, which maintains the crossover frequency and the phase margin of the loop gain much closer to the design goals than the conventional loop, even with large variations of the power stage elements. Furthermore, the proposed scheme can achieve that the power stage seen by the voltage regulator becomes a first order system like current-mode controls do. A 5 V-5 A, 50 kHz buck prototype operating from an input voltage ranging from 15 V to 25 V has been experimentally tested with different LC output filters and load conditions, including discontinuous conduction mode. Small-signal and large signal measurements on the prototype have been carried out, showing the robustness properties achieved by the proposed loop.
基于双控制器方案的DC-DC开关变换器稳健性电压模式控制
本文的目的是提出一种模拟和鲁棒的降压型变换器电压模式控制回路,即使功率级元件变化很大,它也能比传统回路保持更接近设计目标的交叉频率和环路增益的相位裕度。此外,该方案可以实现稳压器所看到的功率级像电流型控制一样成为一阶系统。在不同的LC输出滤波器和负载条件下(包括不连续导通模式),实验测试了一个5 V-5 A、50 kHz的降压样机,工作电压范围为15 V至25 V。在样机上进行了小信号和大信号的测量,表明了所提出的回路所具有的鲁棒性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信