{"title":"Reconfigurable analog-to-digital converter for implantable bioimpedance monitoring","authors":"Terence C. Randall, I. Mahbub, S. Islam","doi":"10.1109/BIOWIRELESS.2015.7152117","DOIUrl":null,"url":null,"abstract":"This paper presents a pipelined analog-to-digital converter (ADC) that is designed for implantable bioimpedance monitoring systems. For bioimpedance spectroscopy where the frequency of the excitation current is swept up to high frequencies, the ADC should be adaptable to improve the power efficiency of the system. The converter in this work can configure its resolution and sampling rate based on the input signal amplitude and frequency, respectively. Furthermore, it can automatically decide its configuration with the help of a novel, low-power automatic adaptation circuit. The converter has 10-bit resolution in high-resolution mode and 8-bit resolution in low-resolution mode. The bandwidth of the ADC is 100 kHz in low-speed mode and 20 MHz in high-speed mode. The SNDR, ENOB and power consumption of the converter in low-speed mode are 58.66 dB, 9.45, and 16 μW in 10-bit mode and 46.56 dB, 7.41, and 9 μW in 8-bit mode.","PeriodicalId":140312,"journal":{"name":"2015 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-07-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIOWIRELESS.2015.7152117","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

This paper presents a pipelined analog-to-digital converter (ADC) that is designed for implantable bioimpedance monitoring systems. For bioimpedance spectroscopy where the frequency of the excitation current is swept up to high frequencies, the ADC should be adaptable to improve the power efficiency of the system. The converter in this work can configure its resolution and sampling rate based on the input signal amplitude and frequency, respectively. Furthermore, it can automatically decide its configuration with the help of a novel, low-power automatic adaptation circuit. The converter has 10-bit resolution in high-resolution mode and 8-bit resolution in low-resolution mode. The bandwidth of the ADC is 100 kHz in low-speed mode and 20 MHz in high-speed mode. The SNDR, ENOB and power consumption of the converter in low-speed mode are 58.66 dB, 9.45, and 16 μW in 10-bit mode and 46.56 dB, 7.41, and 9 μW in 8-bit mode.
用于植入式生物阻抗监测的可重构模数转换器
本文提出了一种用于植入式生物阻抗监测系统的流水线模数转换器(ADC)。对于生物阻抗谱,其中激励电流的频率扫频到高频,ADC应适应,以提高系统的功率效率。该转换器可以根据输入信号的幅值和频率分别配置其分辨率和采样率。此外,它还可以通过一种新颖的低功耗自动自适应电路来自动确定其配置。该转换器在高分辨率模式下具有10位分辨率,在低分辨率模式下具有8位分辨率。ADC的带宽在低速模式下为100khz,在高速模式下为20mhz。低速模式下的SNDR、ENOB和功耗在10位模式下分别为58.66 dB、9.45和16 μW,在8位模式下分别为46.56 dB、7.41和9 μW。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信