{"title":"An invariant diagnostic marker for the identification of partial discharge sources in electrical apparatus","authors":"A. Contin, G. Montanari, M. Conti, M. Cacciari","doi":"10.1109/ICSD.2001.955626","DOIUrl":null,"url":null,"abstract":"The problem of the identification of Partial Discharge (PD) phenomena in electrical apparatus, where the PD signals detected at the measurement bus can be significantly attenuated and distorted by the transmission path, is dealt with. Recently, it has been shown that the shape parameter of the Weibull function, /spl beta/, can be used to identify PD-source typologies, even in the presence of different PD phenomena simultaneously active. This paper provides further contributions to the validation of /spl beta/ as aging marker, focusing on the behavior of /spl beta/ in the presence of distortion and attenuation of PD signals due to the influence of the transmission path between the detection point and the PD source. For this purpose, different PD sources, such as internal void, surface and corona discharges, were considered in the experiments.","PeriodicalId":239585,"journal":{"name":"ICSD'01. Proceedings of the 20001 IEEE 7th International Conference on Solid Dielectrics (Cat. No.01CH37117)","volume":"13 3","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ICSD'01. Proceedings of the 20001 IEEE 7th International Conference on Solid Dielectrics (Cat. No.01CH37117)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSD.2001.955626","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9
Abstract
The problem of the identification of Partial Discharge (PD) phenomena in electrical apparatus, where the PD signals detected at the measurement bus can be significantly attenuated and distorted by the transmission path, is dealt with. Recently, it has been shown that the shape parameter of the Weibull function, /spl beta/, can be used to identify PD-source typologies, even in the presence of different PD phenomena simultaneously active. This paper provides further contributions to the validation of /spl beta/ as aging marker, focusing on the behavior of /spl beta/ in the presence of distortion and attenuation of PD signals due to the influence of the transmission path between the detection point and the PD source. For this purpose, different PD sources, such as internal void, surface and corona discharges, were considered in the experiments.