{"title":"A 19.6 dB Input Power Range 403 MHz Rectifier Based on Quality Factor in Matching Technique","authors":"NgocDuc Au, C. Seo, K. Park, Seungmo Hong","doi":"10.1109/WPTC45513.2019.9055538","DOIUrl":null,"url":null,"abstract":"To extend the input power range and increase RF sensitivity for energy harvesting in medical implant communication service (MICS) band, a high quality (Q) matching network is applied in 403 MHz rectifier circuit. In this proposed design, a finite unload Q series inductor is placed between a pair of shunt capacitors to enhance the overall load Q factor of impedance matching network when compared with conventional type. By using lump components, the compact size of rectifier is 1.4 cm x 0.8 cm that suitable for medical implant devices in human body tissue. The compact-size rectifier has the measured efficiency $(\\eta)$ where the input power range for $\\eta$ above 50.1 % is from -8.1 dBm (RF sensitivity) to 11.5 dBm and thus, the input power range of 19.6 dB is achieved. At 5 dBm the peak efficiency is 68.1 %.","PeriodicalId":148719,"journal":{"name":"2019 IEEE Wireless Power Transfer Conference (WPTC)","volume":"36 1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Wireless Power Transfer Conference (WPTC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/WPTC45513.2019.9055538","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
To extend the input power range and increase RF sensitivity for energy harvesting in medical implant communication service (MICS) band, a high quality (Q) matching network is applied in 403 MHz rectifier circuit. In this proposed design, a finite unload Q series inductor is placed between a pair of shunt capacitors to enhance the overall load Q factor of impedance matching network when compared with conventional type. By using lump components, the compact size of rectifier is 1.4 cm x 0.8 cm that suitable for medical implant devices in human body tissue. The compact-size rectifier has the measured efficiency $(\eta)$ where the input power range for $\eta$ above 50.1 % is from -8.1 dBm (RF sensitivity) to 11.5 dBm and thus, the input power range of 19.6 dB is achieved. At 5 dBm the peak efficiency is 68.1 %.
为了扩大医疗植入通信服务(MICS)频段能量采集的输入功率范围和提高射频灵敏度,在403mhz整流电路中采用了高质量匹配网络。在此设计中,在一对并联电容之间放置一个有限卸载Q系列电感器,以提高阻抗匹配网络的整体负载Q因子。采用块状元件,整流器的紧凑尺寸为1.4 cm x 0.8 cm,适合于人体组织中的医疗植入装置。紧凑尺寸的整流器具有测量效率$(\eta)$,其中$\eta$高于50.1%的输入功率范围从-8.1 dBm (RF灵敏度)到11.5 dBm,因此,输入功率范围为19.6 dB。在5 dBm时,峰值效率为68.1%。