Shiping Zuo, Jianfeng Li, Mingjie Dong, Guangsheng Li, Ran Jiao, Guotong Li
{"title":"A 4-DOF Parallel External fixator for Foot-Ankle Deformity Correction","authors":"Shiping Zuo, Jianfeng Li, Mingjie Dong, Guangsheng Li, Ran Jiao, Guotong Li","doi":"10.1109/RCAR54675.2022.9872260","DOIUrl":null,"url":null,"abstract":"Foot-ankle deformity is one of the common complaints in orthopaedic surgery. The external fixator has been selected as the medical apparatus to help with gradual correction, and the configuration may affect the final correction results. It is meaningful to design novel parallel external fixator with deformity-targeting property. Taking the main foot-ankle deformities with four corrective degree-of-freedom (c-DOF) as research object, a 4-DOF parallel configuration is proposed in this paper. Considering several applicable conditions, lower-mobility kinematic struts are selected to provide desired constraints. Then, inverse kinematic model and Jacobian matrix are derived. Finally, after the structural design, clinical case is simulated to prove the applicability of the parallel external fixator.","PeriodicalId":304963,"journal":{"name":"2022 IEEE International Conference on Real-time Computing and Robotics (RCAR)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE International Conference on Real-time Computing and Robotics (RCAR)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RCAR54675.2022.9872260","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Foot-ankle deformity is one of the common complaints in orthopaedic surgery. The external fixator has been selected as the medical apparatus to help with gradual correction, and the configuration may affect the final correction results. It is meaningful to design novel parallel external fixator with deformity-targeting property. Taking the main foot-ankle deformities with four corrective degree-of-freedom (c-DOF) as research object, a 4-DOF parallel configuration is proposed in this paper. Considering several applicable conditions, lower-mobility kinematic struts are selected to provide desired constraints. Then, inverse kinematic model and Jacobian matrix are derived. Finally, after the structural design, clinical case is simulated to prove the applicability of the parallel external fixator.