Design of Photoelectric Signal Parameter Test System for Liquid Crystal Filters

Bangqi Guo, Chujiao Peng
{"title":"Design of Photoelectric Signal Parameter Test System for Liquid Crystal Filters","authors":"Bangqi Guo, Chujiao Peng","doi":"10.1109/CONF-SPML54095.2021.00014","DOIUrl":null,"url":null,"abstract":"The system studied in this study is specifically used for the measurement of the optical transmittance of liquid crystal filters. In practical applications, liquid crystal filters are mainly used in the production of welding masks. Therefore, the optical transmittance of the liquid crystal filter is an important parameter of the entire liquid crystal material, which is of great significance to the performance of the welding mask products. This study is aimed at the optical transmittance measurement system with white light as the light source. The system include s a light source, an integrating sphere, and a luxmeter. The core point of this system is that the photodetector detects the electrical signal at the opening on the side of the integrating sphere and compares it with the standard illuminance meter. The light intensity measured at the front opening is subjected to a fitting calibration, so that the detected optical signal measured at the opening on the side of the integrating sphere represents the light intensity at the front opening of the integrating sphere. The equipment needs to be measured in a dark room. The test results prove that the low collimation of the light source has a certain impact on the experimental results. The test results show that after debugging, the light signal detected at the opening on the side of the integrating sphere can accurately represent the light intensity measured by the standard illuminance meter at the front opening.","PeriodicalId":415094,"journal":{"name":"2021 International Conference on Signal Processing and Machine Learning (CONF-SPML)","volume":" 5","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Conference on Signal Processing and Machine Learning (CONF-SPML)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CONF-SPML54095.2021.00014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The system studied in this study is specifically used for the measurement of the optical transmittance of liquid crystal filters. In practical applications, liquid crystal filters are mainly used in the production of welding masks. Therefore, the optical transmittance of the liquid crystal filter is an important parameter of the entire liquid crystal material, which is of great significance to the performance of the welding mask products. This study is aimed at the optical transmittance measurement system with white light as the light source. The system include s a light source, an integrating sphere, and a luxmeter. The core point of this system is that the photodetector detects the electrical signal at the opening on the side of the integrating sphere and compares it with the standard illuminance meter. The light intensity measured at the front opening is subjected to a fitting calibration, so that the detected optical signal measured at the opening on the side of the integrating sphere represents the light intensity at the front opening of the integrating sphere. The equipment needs to be measured in a dark room. The test results prove that the low collimation of the light source has a certain impact on the experimental results. The test results show that after debugging, the light signal detected at the opening on the side of the integrating sphere can accurately represent the light intensity measured by the standard illuminance meter at the front opening.
液晶滤波器光电信号参数测试系统的设计
本研究所研究的系统是专门用于液晶滤光片透光率的测量。在实际应用中,液晶滤光片主要用于焊接口罩的生产。因此,液晶滤光片的光学透过率是整个液晶材料的重要参数,对焊接掩模产品的性能具有重要意义。本课题针对以白光为光源的光学透射率测量系统进行了研究。该系统包括一个光源、一个积分球和一个luxmeter。该系统的核心是光电探测器检测积分球侧面开口处的电信号,并与标准照度计进行比较。将积分球前开口处测得的光强进行拟合标定,使积分球侧面开口处测得的检测光信号代表积分球前开口处的光强。设备需要在暗室里进行测量。实验结果证明,光源的低准直对实验结果有一定的影响。测试结果表明,经过调试,积分球侧面开口处检测到的光信号能够准确代表前开口处标准照度计测得的光强。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信