Limitations of overlap control for energy balancing of the alternate arm converter under imbalanced ac grid conditions

Jinke Li, H. Wickramasinghe, G. Konstantinou, J. Pou, Xinmin Jin
{"title":"Limitations of overlap control for energy balancing of the alternate arm converter under imbalanced ac grid conditions","authors":"Jinke Li, H. Wickramasinghe, G. Konstantinou, J. Pou, Xinmin Jin","doi":"10.1109/ACEPT.2017.8168596","DOIUrl":null,"url":null,"abstract":"Energy balancing of the alternate arm converter (AAC) takes place during the overlap period, when a circulating current flows through both arms of the converter. In this paper, the limitations of the commonly used energy balancing methods of the AAC under grid imbalances are demonstrated. It is shown that the overlap control can only provide sufficient energy balancing for a relatively limited voltage imbalance degree of the ac voltages and larger imbalances greatly impact the energy balancing of the AAC. The limitations of the overlap control are demonstrated through real-time digital simulations of an 800-MVA benchmark AAC model under single-phase, phase-to-phase and three-phase ac imbalances with varying imbalance degrees.","PeriodicalId":217916,"journal":{"name":"2017 Asian Conference on Energy, Power and Transportation Electrification (ACEPT)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 Asian Conference on Energy, Power and Transportation Electrification (ACEPT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ACEPT.2017.8168596","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Energy balancing of the alternate arm converter (AAC) takes place during the overlap period, when a circulating current flows through both arms of the converter. In this paper, the limitations of the commonly used energy balancing methods of the AAC under grid imbalances are demonstrated. It is shown that the overlap control can only provide sufficient energy balancing for a relatively limited voltage imbalance degree of the ac voltages and larger imbalances greatly impact the energy balancing of the AAC. The limitations of the overlap control are demonstrated through real-time digital simulations of an 800-MVA benchmark AAC model under single-phase, phase-to-phase and three-phase ac imbalances with varying imbalance degrees.
交流电网不平衡条件下交替臂变流器能量平衡重叠控制的局限性
交替臂变换器(AAC)的能量平衡发生在重叠期间,当一个循环电流流过变换器的两个臂时。本文论证了电网不平衡条件下常用的AAC能量平衡方法的局限性。结果表明,重叠控制只能为交流电压相对有限的电压不平衡程度提供足够的能量平衡,较大的不平衡将极大地影响ac的能量平衡。通过对一个800-MVA基准AAC模型在不同不平衡程度的单相、相对相和三相交流不平衡情况下的实时数字仿真,证明了重叠控制的局限性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信