Emulations of Overvoltage and Overcurrent Relays In Transmission Lines

H. Amreiz, A. Janbey, M. Darwish
{"title":"Emulations of Overvoltage and Overcurrent Relays In Transmission Lines","authors":"H. Amreiz, A. Janbey, M. Darwish","doi":"10.1109/UPEC55022.2022.9917757","DOIUrl":null,"url":null,"abstract":"An “Over Voltage Relay” is one of the protective relays which operates when the voltage exceeds a preset value. In a typical application the over voltage relay is used for over voltage protection, which is connected to a potential transformer, and calibrated to operate at or above a specific voltage level. An “Under Voltage Relay” and an “Over Current Relay” are also protective relays which operate when the voltage is reduced, or the current is increased below or above a preset value. In a typical application these relays are connected to potential transformers, and calibrated to operate at, above or below a specific voltage or current levels. The emulator used in paper simulated experiments of all three types of relays mentioned above. The transmission line emulator used in this paper is an HVAC transmission line of length of 180 km. The transmission line of the emulator can be used as a 3-phase transmission line of 180 km length or as a single-phase transmission line of 540 km long. This transmission line in the emulator is divided into 6 $\\pi$ sections and each $\\pi$ section is 30 km long. The line inductance of the transmission line of the emulator is examined for every 30 km and the line capacitance is examined for every 15 km. The line parameters of the emulator (RLC) for the 400kV transmission line are: 0. 02978$\\Omega$/km, 1.06 mH/km and 0.0146 $\\mu$F/km, respectively.","PeriodicalId":371561,"journal":{"name":"2022 57th International Universities Power Engineering Conference (UPEC)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 57th International Universities Power Engineering Conference (UPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UPEC55022.2022.9917757","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

An “Over Voltage Relay” is one of the protective relays which operates when the voltage exceeds a preset value. In a typical application the over voltage relay is used for over voltage protection, which is connected to a potential transformer, and calibrated to operate at or above a specific voltage level. An “Under Voltage Relay” and an “Over Current Relay” are also protective relays which operate when the voltage is reduced, or the current is increased below or above a preset value. In a typical application these relays are connected to potential transformers, and calibrated to operate at, above or below a specific voltage or current levels. The emulator used in paper simulated experiments of all three types of relays mentioned above. The transmission line emulator used in this paper is an HVAC transmission line of length of 180 km. The transmission line of the emulator can be used as a 3-phase transmission line of 180 km length or as a single-phase transmission line of 540 km long. This transmission line in the emulator is divided into 6 $\pi$ sections and each $\pi$ section is 30 km long. The line inductance of the transmission line of the emulator is examined for every 30 km and the line capacitance is examined for every 15 km. The line parameters of the emulator (RLC) for the 400kV transmission line are: 0. 02978$\Omega$/km, 1.06 mH/km and 0.0146 $\mu$F/km, respectively.
输电线路中过压和过流继电器的仿真
“过压继电器”是一种保护继电器,当电压超过预设值时,它就会工作。在典型应用中,过压继电器用于过压保护,它连接到电位互感器上,并经过校准以达到或高于特定电压水平。“欠压继电器”和“过流继电器”也是保护继电器,当电压降低或电流低于或高于预设值时,它们也会工作。在典型应用中,这些继电器连接到电位变压器,并经过校准以在高于或低于特定电压或电流水平下工作。本文所使用的仿真器对上述三种继电器进行了仿真实验。本文所使用的传输线仿真器是一条长度为180 km的暖通空调传输线。仿真器的传输线可以作为180公里长的三相传输线,也可以作为540公里长的单相传输线。仿真器中的传输线分为6个$\pi$段,每个$\pi$段长30公里。仿真器传输线的线路电感每隔30公里检测一次,线路电容每隔15公里检测一次。400kV输电线路仿真器(RLC)的线路参数为:0。02978 $\Omega$ /km、1.06 mH/km和0.0146 $\mu$ F/km。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信