Coefficients for the Derivation of an ST Sensitive Patch Based Lead System from the 12 Lead Electrocardiogram

M. Jennings, A. Rababah, Daniel Güldenring, J. Mclaughlin, D. Finlay
{"title":"Coefficients for the Derivation of an ST Sensitive Patch Based Lead System from the 12 Lead Electrocardiogram","authors":"M. Jennings, A. Rababah, Daniel Güldenring, J. Mclaughlin, D. Finlay","doi":"10.23919/cinc53138.2021.9662649","DOIUrl":null,"url":null,"abstract":"Background: There are limited datasets available to facilitate the evaluation of patch-based lead systems, so the leads must be derived from existing data, mainly the 12-lead ECG. We have previously introduced a short spaced lead (SSL) system consisting of two leads with the largest ST segment changes during ischaemic-type episodes. In this study, we aim to evaluate the derivation of this patch-based lead system from the 12-lead ECG. Method: Thoracic body surface potential maps (BSPM) were recorded from $n=734$ patients. Using Laplacian interpolation, each recording was expanded to the 352-node Dalhousie torso. The eight independent channels of the 12-lead ECG were extracted (I, II, V1-V6) with the two leads of the SSL patch Coefficients were derived using linear regression from the 12-lead ECG to the SSL patch. Results: The median Pearson correlation coefficients (CC) and root mean square error (RMSE) for each lead were calculated as follows (CC/RMSE): $0.986/74.3 \\mu V$ (ST monitoring lead); $0.976/65.3 \\mu V$ (spatially orthogonal lead). Conclusion: We have developed coefficients that allow the derivation of a patch-based lead system from the 12-lead ECG. Given the high correlation, it is possible to generate short spaced lead systems from existing diagnostic lead systems, however, amplitude errors are introduced in the process.","PeriodicalId":126746,"journal":{"name":"2021 Computing in Cardiology (CinC)","volume":"50 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 Computing in Cardiology (CinC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/cinc53138.2021.9662649","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: There are limited datasets available to facilitate the evaluation of patch-based lead systems, so the leads must be derived from existing data, mainly the 12-lead ECG. We have previously introduced a short spaced lead (SSL) system consisting of two leads with the largest ST segment changes during ischaemic-type episodes. In this study, we aim to evaluate the derivation of this patch-based lead system from the 12-lead ECG. Method: Thoracic body surface potential maps (BSPM) were recorded from $n=734$ patients. Using Laplacian interpolation, each recording was expanded to the 352-node Dalhousie torso. The eight independent channels of the 12-lead ECG were extracted (I, II, V1-V6) with the two leads of the SSL patch Coefficients were derived using linear regression from the 12-lead ECG to the SSL patch. Results: The median Pearson correlation coefficients (CC) and root mean square error (RMSE) for each lead were calculated as follows (CC/RMSE): $0.986/74.3 \mu V$ (ST monitoring lead); $0.976/65.3 \mu V$ (spatially orthogonal lead). Conclusion: We have developed coefficients that allow the derivation of a patch-based lead system from the 12-lead ECG. Given the high correlation, it is possible to generate short spaced lead systems from existing diagnostic lead systems, however, amplitude errors are introduced in the process.
从12导联心电图推导ST敏感贴片导联系统的系数
背景:可用于评估贴片导联系统的数据集有限,因此导联必须来自现有数据,主要是12导联心电图。我们之前介绍过一种短间隔导联(SSL)系统,该系统由两条导联组成,在缺血型发作期间ST段变化最大。在这项研究中,我们的目的是评估这种基于贴片的导联系统从12导联心电图的推导。方法:记录734例患者的胸椎体表电位图(BSPM)。使用拉普拉斯插值,每个记录被扩展到352节点的达尔豪西躯干。提取了12导联心电图的8个独立通道(I、II、V1-V6),并利用SSL贴片的两导联提取了12导联心电图与SSL贴片的线性回归系数。结果:各导联的中位Pearson相关系数(CC)和均方根误差(RMSE)计算如下(CC/RMSE): $0.986/74.3 \mu V$ (ST监测导联);$0.976/65.3 \mu V$(空间正交引线)。结论:我们已经开发了系数,允许从12导联心电图中推导出基于贴片的导联系统。鉴于高相关性,可以从现有的诊断导联系统中生成短间隔导联系统,然而,在此过程中引入幅度误差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信