{"title":"Safe and time-optimized power transfer between two induction loads supplied by a single generator","authors":"M. Bendaas, S. Bacha, J. Ferrieux, J. Rognon","doi":"10.1109/IECON.1993.339129","DOIUrl":null,"url":null,"abstract":"The paper deals with the problem of transferring power between different induction loads supplied by the same current generator, in as a short time as possible. In the reference solution, the system is completely stopped: it needs a long time for the current to reach zero, and then its new value, because the DC link inductance must be demagnetized and remagnetized; moreover an auxiliary starter is needed. In the proposed solution, the input of the current inverter is short-circuited whenever a transfer must be performed; the inductance remains magnetized and the current at the output of the inverter varies very quickly: the transfer time is minimal and no starter is needed; the specific inverter control laws used to insure natural commutation are described. The paper also presents average models of the system, obtained by combining average and dynamic or static first harmonic modelling methods.<<ETX>>","PeriodicalId":132101,"journal":{"name":"Proceedings of IECON '93 - 19th Annual Conference of IEEE Industrial Electronics","volume":"2022 4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of IECON '93 - 19th Annual Conference of IEEE Industrial Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECON.1993.339129","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The paper deals with the problem of transferring power between different induction loads supplied by the same current generator, in as a short time as possible. In the reference solution, the system is completely stopped: it needs a long time for the current to reach zero, and then its new value, because the DC link inductance must be demagnetized and remagnetized; moreover an auxiliary starter is needed. In the proposed solution, the input of the current inverter is short-circuited whenever a transfer must be performed; the inductance remains magnetized and the current at the output of the inverter varies very quickly: the transfer time is minimal and no starter is needed; the specific inverter control laws used to insure natural commutation are described. The paper also presents average models of the system, obtained by combining average and dynamic or static first harmonic modelling methods.<>
安全,时间优化的电力传输之间的两个感应负载提供了一个单一的发电机
本文研究了在同一电流发电机提供的不同感应负载之间,在尽可能短的时间内进行功率转换的问题。在参考方案中,系统是完全停止的:它需要很长时间才能使电流达到零,然后再达到它的新值,因为必须对直流链路电感进行退磁和再磁化;此外,还需要一个辅助起动器。在提出的解决方案中,只要必须进行转换,电流逆变器的输入就会短路;电感保持磁化,逆变器输出端的电流变化非常快:转移时间最短,不需要启动器;描述了用于保证自然换相的逆变器的具体控制律。文中还给出了系统的平均模型,该模型是由平均模型和动、静一谐建模方法相结合得到的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信